PAGE 30
CHECK FOR ENGINE FLOODING
There's a chance that if you've over used the pull start
mechanism, you may have flooded the two-stroke engine.
This is very simple to check and fix.
Open up the casing and remove the black lead that covers
the plug.
If the spark plug is damp with fuel then the engine is flood-
ed. Remove the plug, and allow the excess fuel to evapo-
rate.
Replace the plug and follow the usual starting procedure.