Sharp 20 P4 - fig. 6
Charger → Sharp 48V/15A Sharp 36V/20A
Sharp
12-24V/20A
Sharp
12-24V/30A
Sharp 24V/30A
Program →
M210
2M210
M308
2M308
2RM121
2RM120
M111, 2M111
B010, 2B010
B120
2B120
Switch
pos
Ah Time (h) Ah Time (h) Ah Time (h) Ah Time (h) Ah Time (h)
WET
0 2,23V/cell 2,4V/cell 2,3V/cell
1 40-49 6,5-7,5 50-64 5,5-6,5 40-60 4,5-6,0 100-119 5,5-6,0 145-174 7,0-7,5
2 50-64 6,5-7,5 65-84 6,0-7,0 65-90 6,5-8,0 120-144 6,0-7,0 175-209 7,5-8,5
3 65-84 6,5-7,5 85-104 6,5-7,0 95-130 7,0-8,0 145-174 7,0-7,5 210-249 8,5-10
4 85-104 7,5-8,5 105-124 7,0-8,0 135-185 8,5-10,5 175-209 7,5-8,5 250-299 10-11
5 105-124 8,5-9,5 125-150 8,0-9,0 190-250 10,5-12,5 210-249 8,5-9,5 300-360 11-12
6 125-150 9,5-11 151-180 9,0-10 250-299 9,5-11
7 150-180 11-12 181-216 10-11,5 300-350 11-12
WET
PULSE
6 145-174 6,5-7,0
7 175-209 7,0-8,0
8 210-249 8,0-9,0
9 250-299 9,0-10
A 300-360 10-11
DRY
6 40-50 10,5-12,5
7 50-70 9,5-13
8 2,26V/cell 2,3V/cell 70-95 9,5-12
9 150-180 >19 181-216 >17,5 95-130 10-13 330-350 >19
A 125-150 16-19 151-180 15-17,5 130-180 13-17,5 250-299 16,5-19
B 105-124 14-16 125-150 12,5-15 210-249 14-16 145-174 12-14
C 85-104 12-15 105-124 12,5-14,5 175-209 12-14 175-209 12-14
D 65-84 12,5-15,5 90-104 12-14 145-174 12-14 210-249 14-16
E 50-64 12,5-16 75-89 12-13,5 120-144 11,5-14 250-299 16,5-19
F 40-49 12,5-15 60-74 11,5-13,5 100-119 12-14 300-350 >19
For more information on charging curves and charging times, please contact your local Micropower
representative or visit www.micropower-group.com.