Sharp 20 P6 - fig. 7
Charger → Sharp 48V/30A Sharp 36V/40A Sharp 24V/45A Sharp 24V/60A
Program →
BB220
2BB220
BB320
2BB320
2BB124
BB120
2BB120
Switch
pos
Ah Time (h) Ah Time (h) Ah Time (h) Ah Time (h)
WET
0 – – – – – – – –
1 145-175 7-8 200-240 7-8 200-234 6-7 300-365 7-8
2 176-210 8-9 241-290 8-9 235-269 7-8 366-435 8-9
3 211-250 9-10 291-345 9-10 270-304 8-8,5 436-520 9-10
4 251-300 10-11 346-410 10-11 305-339 8,5-9 521-625 10-11
5 301-360 11-12 411-440 11-12 340-375 9-10 626-660 11-12
WET
PULSE
6 175-210 7-8 240-290 7-8 235-289 7-8 365-435 7-8
7 211-250 8-9 291-345 8-9 290-344 8-9 436-520 8-9
8 251-300 9-10 346-410 9-10 345-399 9-10 521-625 9-10
9 301-360 10-11 411-500 10-11 400-454 10-11 626-750 10-12
A – – – – – – – –
DRY
A – – – – – – – –
B 300-350 >16 416-440 >17 340-375 >16 626-750 >17
C 251-299 14-16 346-415 14-17 305-339 13-14 521-625 14-17
D 211-250 12-14 291-345 13-14 270-304 13-14 436-520 12-14
E 176-210 12-14 241-290 10-13 235-269 13-14 366-435 12-14
F 145-175 11-12 201-240 11-12 200-234 11-12 300-365 11-12
For more information on charging curves and charging times, please contact your local Micropower
representative or visit www.micropower-group.com.
149