32R-S480
CR32S48
EX1 FAO VOLUME 24 0-50(00h-32h) Must be set to "24"
EX2 CC-POSITION 21 0-127(00h-7Fh)
EX3 INT 7A 0-255(00h-FFh) Must be set to "7A"
EX4 A-ATT 5A 0-127
OP1 OPTION1 BA 0-255(00h-FFh) Must be set to "B7" (32R-S480), "A7" (CR32S48)
OP2 OPTION2 01 0-7(00h-07h) Must be set to "09"
M01 INPUT LEVEL 09 0-15(00h-0Fh) Must be set to "09"
M02 MTS VCO 24 0-63(00h-3Fh)
M03 FILTER 1F 0-63(00h-3Fh)
M04 WIDEBAND 18 0-63(00h-3Fh)
M05 SPECTRAL 10 0-63(00h-3Fh)
P01 CONTRAST-PIP 32 0-127(00h-7Fh)
P02 TINT-PIP 29 0-63(00h-3Fh) Must be set to "29"
P03 COLOR-SAT-PIP 32 0-127(00h-7Fh)
P04 Y-OFFSET-PIP 09 0-31(00h-1Fh) Must be set to "09"
P05 HXA-PIP 0A 0-255(00h-FFh) Must be set to "0A"
P06 HADJ-PIP 00 0-15(00h-0Fh) Must be set to "00"
P07 FREE RUN-PIP 0B 0-15(00h-0Fh) Must be set to "0B"
P08 TINT-PIP-INPUT 24 0-63(00h-3Fh) Must be set to "24"
SERVICE
NUMBER
DATA
ADJUSTMENT ITEM
INITIAL VALUE
RANGE
ADJUSTMENT CONTENTS
Table - A
NECESSARY UNNECESSARY
ADJUSTMENT
PART REPLACED
IC2001
IC201
X
Data is stored in IC2102.
The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01).
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2102.
NOTES
X
IC2102
IC3001
CRT
IC1801
Holding down both the VOL-up and CH-up buttons on the TV set in
the service mode for more than 2 seconds will automatically write the
above initial values into IC2102. Then perform a complete adjustment.
Adjust items related to picture tube only.
Adjust items related to MTS only (M01~M05).
Adjust items related to P-IN-P only (P01~P08).