8
32U-S50, 32U-S60
36U-S60
M01 INPUT LEVEL 09 0-15(00h-0Fh)
M02 MTS VCO 24 0-63(00h-3Fh)
M03 FILTER 1F 0-63(00h-3Fh)
M04 WIDEBAND 18 0-63(00h-3Fh)
M05 SPECTRAL 10 0-63(00h-3Fh)
SERVICE
NUMBER
DATA
ADJUSTMENT ITEM
INITIAL VALUE
RANGE
ADJUSTMENT CONTENTS
Table - A
NECESSARY UNNECESSARY
ADJUSTMENT
PART REPLACED
IC2001
IC201
X
Data is stored in IC2102.
The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01).
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2102.
NOTES
X
IC2102
IC3001
CRT
IC1801
Holding down both the VOL-up and CH-up buttons on the TV set in
the service mode for more than 2 seconds will automatically write the
above initial values into IC2102. Then perform a complete adjustment.
Adjust items related to picture tube only.
Adjust items related to MTS only (M01~M05).
Adjust items related to P-IN-P only (P01~P08).
Table - B
X
X
X
X