AE-XM30GR
1 – 4
[4] ELECTRICAL PARTS
[5] WIRING DIAGRAMS
2-Room
18 12 OFF - 4.86 3.24 OFF - 8.1 (3.6-9.0j 11.2 (3.8-15.1) 2450 (830-3300)
18 9 OFF - 5.40 2.70 OFF - 8.1 (3.6-9.0j 11.2 (3.8-15.1) 2450 (830-3300)
18 7 OFF - 5.54 2.16 OFF - 7.7 (3.6-9.0j 10.1 (3.8-15.1) 2200 (830-3300)
12 12 OFF OFF 3.8 3.8 OFF OFF 7.6 (2.6-8.0j 11.9 (3.3-13.3) 2600 (730-2900)
12 09 OFF OFF 3.8 2.9 OFF OFF 6.7 (2.6-8.0j 10.3 (3.3-13.3) 2250 (730-2900)
12 07 OFF OFF 3.9 2.2 OFF OFF 6.1 (2.6-8.0) 8.7 (3.3-13.3) 1900(730-2900)
09 09 OFF OFF 2.9 2.9 OFF OFF 5.8 (2.6-8.0) 8.5 (3.3-13.3) 1850 (730-2900)
09 07 OFF OFF 3.0 2.3 OFF OFF 5.3(2.6-7.3) 6.9 (3.3-11.0) 1510 (730-2400)
07 07 OFF OFF 2.4 2.4 OFF OFF 4.8(2.6-6.4) 6.2 (3.3-9.2) 1350 (730-2000)
1-Room
18 OFF OFF OFF 5.0 OFF OFF - 6.2 (2.6-7.4) 10.1 (3.3-13.7) 2200 (730-3000)
12 OFF OFF OFF 3.8 OFF OFF OFF 3.8 (1.8-5.2) 7.3(2.9-10.1) 1600 (640-2200)
09 OFF OFF OFF 2.9 OFF OFF OFF 2.9 (1.8-4.0) 5.2 (2.9-8.0) 1130 (640-1750)
07 OFF OFF OFF 2.4 OFF OFF OFF 2.4 (1.8-3.4) 4.0 (2.9-6.2) 870 (640-1350)
Compressor DA220A2F-20L Hermetically sealed DC twin rotary
Outdoor fan motor MLB051 230V, 50Hz
Outdoor fan motor capacitor 500V, 3F
Fuse 1,2 QFS-GA065JBZZ(20A,250V)
Fuse 6 QFS-GA064JBZZ(1A,250V)
Fuse 3,4 QFS-GA062JBZZ(3.15A,250V)
Operat-
ing Status
Combination of Indoor
Units
Heating Capacity (kW) Running Current (A)
Power Consumption
(W)
A B C D A B C D RATING (Min.-Max.) RATING (Min.-Max.) RATING (Min.-Max.)
CC298