EasyManua.ls Logo

Sharp AH-X079E - Performance Curves

Sharp AH-X079E
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
AH-X079E/X099E
AY-X079E/X099E
PERFORMANCE CURVES
Figure P-1. At Cooling for AH-X079E Figure P-2. At Cooling for AH-X099E
25 30 35 40
2.0
2.2
2.4
2.6
10
12
14
600
800
1000
1200
Cooling capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)
1) Indoor fan speed: Hi
2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front" 
3) Indoor air temp. : 27˚C
NOTE:
(Running frequency: 52HZ)
25 30 35 40
2.2
2.4
2.6
2.8
10
12
14
600
800
1000
1200
(Running frequency: 88Hz)
Cooling capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)