Quick Reference Guide:  AR-M237/M277
Simulation
10
Simulation: Diagnostics, Setup, Adjustment Value Input, and Data Display
Entering the Simulation Mode
1. Copy mode key ON → Program key ON → Asterisk (*) key 
ON → CLEAR key ON →Asterisk key ON → Ready for 
input of a main code of simulation
2. Entering a main code with the 10-key → START key ON
3. Entering a sub-code with the 10-key → START key ON
4. Select an item with the scroll key and the item key.
5. The machine enters the mode corresponding to the 
selected item.
a) Press START key or EXECUTE key to start 
the simulation  operation.
b) To cancel the current simulation mode or to 
change the main code or the sub code, press 
the user setup key. 
*Canceling the simulation mode to return to the
normal mode:  
Simulation List 
Please refer to the Simulation List (pages 1 through 10) that follows.
6. Press CA key.
How to Change the Simulation Adjustment Value Set by the Touch Panel 
in the Adjustment Value Entry Process
Target SIM List
Touch Panel Operating Procedure