AR-M350 SIMULATIONS 10-72
<This mode is for development, and inhibited in the market.>
<Setup for send>
<Result of MODEM writing>
<List of display values>
66-33
Purpose Setup
Function (Content) Used to check signal detection.
Section FAX
Item Operation
Operation/Procedure When the signal is detected, the display is
highlighted.
66-34
Purpose Setup
Function (Content) Used to measure and display the communication
time.
Section FAX
Item Operation
Operation/Procedure The time spent for communication is measured.
Send/receives performed in the normal mode.
The communication time is displayed with the
simulation. (unit: ms)
Communication means memory transmission
Image quality Normal
Density Thin
ECM ON
Sender record OFF
66-35
Purpose Operation test, check
Function (Content) Modem program rewriting.
Section FAX
Item Operation
Operation/Procedure The modem program in the FAX program is
rewritten.
1) Select with 10 digit key pad and press START
to execute the following.
1: MODEM program rewrite
2:Not clear
2) Check the check sum value (loader).
If it is OK, the test is normally completed.
If NG, the check sum value
(1 byte = hexadecimal) is displayed.
3) If the check sum value is NG, the MODEM
result is also NG.
4) The Modem rewrite result is displayed.
SIMULATION 66-33
SIGNAL DETECT CHECK.
BUSY TONE
CNG CED FNET DTM
SIMULATION 66-34
COMMUNICATION TIME DISPLAY.
***** ms
COMPLETE Writing completed
81 Check sum error
82 Write error
83 Delete error
84 Verify error
NG Due to loader error
66-36
Purpose Operation test, check
Function (Content) Used to check interface between MFPC and
MDMC. Check is made in the data line or the
command line.
Section FAX
Item Operation
Operation/Procedure 1) Select with 10 digit key pad and press START.
2) When check is "repeat," the operation is
executed until the result becomes NG or
CUSTOM SETTING is pressed.
1 MFPC <- MDMC Data line once only
2 MFPC -> MDMC Data line once only
3 MFPC <- MDMC Data line repeat
4 MFPC -> MDMC Data line repeat
5 MFPC <- MDMC Command line once only
6 MFPC -> MDMC Command line once only
7 MFPC <- MDMC Command line repeat
8 MFPC -> MDMC Command line repeat
SIMULATION 66-35
MODEM PROGRAM RELOAD.
ARE YOU SURE ?
1. YES
2. NO
1
SIMULATION 66-35
MODEM PROGRAM RELOAD. EXECUTING...
LOADER...(OK or Check Sum value 1 byte (hexadecimal))
MODEM...(COMPLETE or NG code 1 byte (Hexadecimal))
SIMULATION 66-35
MODEM PROGRAM RELOAD.
LOADER...OK
MODEM...COMPLETE
Press [START] key.
After completion of writing
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
1. MFPC<-MDMC(DATA once)
2. MFPC->MDMC(DATA once)
3. MFPC<-MDMC(DATA repeat)
4. MFPC->MDMC(DATA repeat)
5. MFPC<-MDMC(CMD once)
6. MFPC->MDMC(CMD once)
7. MFPC<-MDMC(CMD repeat)
8. MFPC->MDMC(CMD repeat)
1
1
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
EXECUTING...
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
EXECUTING...(OK or NG)
Press [START] key.
When check is "once" or "repeat"
and the result is NG
When check is "repeat" and
[CUSTOM SETTING] key is pressed.
 +   !" #$%&'