CHAPTER 1. PRODUCT SPECIFICATION
[1] SPECIFICATION............................................ 1-1
[2] EXTERNAL DIMENSION............................... 1-2
[3] WIRING DIAGRM........................................... 1-3
[4] ELECTRICAL PARTS..................................... 1-4
CHAPTER 2. EXPLAMATION OF CIRCUIT AND
OPERATION
[1] BLOCK DIAGRAMS....................................... 2-1
[2] MICROCOMPUTER CONTROL SYSTEM.... 2-3
[3] FUNCTION..................................................... 2-8
CHAPTER 3. FUNCTION AND OPERATION OF
PROTECTIVE PROCEDURES
[1] PROTECTION DEVICE FUNCTIONS AND
OPERATIONS................................................ 3-1
[2] AIR/AIR HEAT PUMP OPERATION IN THER-
MISTOR ERROR........................................... 3-3
[3] THERMISTOR TEMPERATURE CHARACTER-
ISTICS............................................................ 3-5
[4] HOW TO OPERATE THE OUTDOOR UNIT
INDEPENDENTLY.......................................... 3-5
[5] GENERAL TROUBLESHOOTING CHART.... 3-6
[6] MALFUNCTION (PARTS) CHECK METH-
OD.................................................................. 7-3
[7] OUTDOOR UNIT CHECK METHOD............ 3-11
[8] TROUBLESHOOTING GUIDE..................... 3-14
[9] CHART......................................................... 3-15
CHAPTER 4. REFRIGERATION CYCLE
[1] SCHEMATIC DIAGRAM................................ 4-1
[2] STANDARD CONDITION.............................. 4-1
[3] TEMPERATURE AT EACH PART AND PRES-
SURE IN 3-WAY VALVE................................. 4-1
[4] PERFORMANCE CURVES............................ 4-1
CHAPTER 5. DISASSEMBLING PROCEDURE
[1] INDOOR UNIT................................................ 5-1
[2] HOW TO REMOVE PLASMACLUSTER
UNIT............................................................... 5-4
[3] DISASSEMBLY OF OUTDOOR UNIT............ 5-5
Parts Guide
Parts marked with "
and performance of the set.
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
SHARP CORPORATION

Questions and Answers

  • G
    gabriellambJul 31, 2025
    Why is my Sharp Heat Pump remote control signal not received?
    • D
      Dawn JohnsJul 31, 2025
      There could be several reasons why your Sharp Heat Pump remote control signal is not being received. It could be due to dead batteries (install new batteries), incorrectly installed batteries (install them in the indicated direction), a lighting fixture being too close or a fluorescent lamp burning out (change the light position or install a new fluorescent lamp), using a Sevick light (replace the light or change its position), an inappropriate operating position/angle (handle appropriately), an open or short circuit in the wiring of the light receiving section (replace the wires), a defective light receiving unit (replace the PWB), or dew condensation on the light receiving unit (take moisture-proof measures for the lead wire outlet).
  • C
    Christina GonzalezAug 5, 2025
    What to do if my Sharp Heat Pump compressor does not start?
    • G
      Gina RomeroAug 5, 2025
      If your Sharp Heat Pump compressor isn't starting, the issue might stem from several causes: an erroneous inter-unit connection (correct the wiring), a damaged IPM (replace the IPM), a dried-up electrolytic capacitor (replace it), a blown outdoor unit fuse (replace the fuse/diode bridge and/or the outdoor unit PWB assembly), a power supply voltage that's too low (ensure it's 198 V or higher), or a compressor lock (apply external impact or replace the compressor).
  • A
    Allison HartmanAug 10, 2025
    Why does my Sharp AY-ZP35PR operation stop and restart repeatedly?
    • R
      Ronald BoydAug 10, 2025
      If your Sharp Heat Pump stops and restarts every few minutes, this could be due to a dried-up electrolytic capacitor (replace the electrolytic capacitor) or a layer short-circuit in the expansion valve coil (replace the coil).
  • S
    Sean PadillaAug 15, 2025
    What to do if there is noise in TV/radio when using Sharp Heat Pump?
    • R
      Ryan PerezAug 15, 2025
      If you're experiencing noise in your TV/radio while using your Sharp Heat Pump, it could be due to grounding wires not connected properly (connect them properly) or the TV/radio being placed too close to the outdoor unit (move it away).
  • D
    Dustin HughesAug 20, 2025
    How to fix Sharp AY-ZP35PR louvers that do not move?
    • M
      Marvin JohnstonAug 20, 2025
      If the louvers on your Sharp Heat Pump aren't moving, check if they are caught in the sliding section (remove or correct the catching section), if the connector is disconnected (CN3, CN4 on relay PWB, louver motor side) (install it correctly), or if there's contact of solder on the PWB (connector section on PWB) (correct the contacting section).
  • K
    Kathleen BryantAug 25, 2025
    What to do if my Sharp AY-ZP35PR indoor unit does not turn on?
    • S
      Sandra FuentesAug 26, 2025
      If the indoor unit of your Sharp Heat Pump isn't turning on, it could be due to a cracked PWB (cracked pattern) or an open-circuit in FU1 (250 V, 2.5A). In both cases, replace the PWB.

Summary

Product Specification

Specification

Details technical specifications for cooling/heating capacity, electrical data, dimensions, noise, and airflow.

External Dimension

Provides detailed dimensional drawings for the indoor and outdoor units.

Wiring Diagram

Illustrates electrical wiring diagrams and self-diagnosis indicators for indoor and outdoor units.

Electrical Parts

Lists electrical components used in the indoor and outdoor units with their models.

Explanation of Circuit and Operation

Block Diagrams

Presents block diagrams for indoor and outdoor unit circuit operations.

Microcomputer Control System

Details electronic control circuit diagrams for indoor and outdoor units.

Function

Explains operational functions, controls, and protective mechanisms of the air conditioner.

Function and Operation of Protective Procedures

Protection Device Functions and Operations

Outlines protection device functions, detection, reset conditions, and error indicators.

Air;Air Heat Pump Operation in Thermistor Error

Describes unit operation during thermistor errors for indoor and outdoor units.

Thermistor Temperature Characteristics

Provides temperature-resistance characteristics for indoor and outdoor unit thermistors.

How to Operate the Outdoor Unit Independently

Details the procedure for operating the outdoor unit independently for testing.

Refrigeration Cycle

Schematic Diagram

Shows the overall refrigeration cycle schematic diagram of the air/air heat pump.

Standard Condition

Lists standard indoor and outdoor operating conditions for testing.

Temperature at Each Part and Pressure in 3-Way Valve

Provides temperature and pressure data at various points in the 3-way valve.

Performance Curves

Presents graphs of performance curves for cooling/heating capacity and input power.

Disassembling Procedure

Indoor Unit

Step-by-step instructions and illustrations for disassembling the indoor unit.

How to Remove Plasmacluster Unit

Specific instructions for removing the plasmacluster unit from the indoor unit.

Disassembly of Outdoor Unit

Step-by-step instructions and illustrations for disassembling the outdoor unit.

Parts Guide

Indoor Unit Parts

Illustrated parts list for the indoor unit.

Accessory Parts

Lists accessory parts included with the unit.

Indoor Packing Parts

Details packing parts for the indoor unit.

Outdoor Unit Parts

Illustrated parts list for the outdoor unit.

Outdoor Packing Parts

Details packing parts for the outdoor unit.

Sharp AY-ZP35PR Specifications

General IconGeneral
BrandSharp
ModelAY-ZP35PR
CategoryHeat Pump
LanguageEnglish

Related product manuals