ER-A410/ER-A420 PROGRAM (PGM2/PGM1) MODE
2 – 19
[JOB#2617]
PROGRAMMING OF THE TIME INTERVAL FOR THE DRAWER
ALARM
MRS = 000
H: PLU PRICE LEVEL auto reset timing
(Available when “PLU PRICE LEVEL reset
=AUTO”)
H
1 item 0
1 receipt 1
XX: 6 MRS = 00000000
A: VAT/TAX AMOUNT PRINTING on SLIP/G.C.RCPT A
Print 0
Not print 1
B: TAXABLE AMOUNT PRINTING on SLIP/G.C.RCPT B
Print 0
Not print 1
C: NET AMOUNT PRINTING on SLIP/G.C.RCPT C
Print 0
Not print 1
D: TIME PRINTING on SLIP/G.C.RCPT D
Print 0
Not print 1
E, F, G, H: Not used (Fixed at "0000")
XX: 7 MRS = 00000000
A, B: Not used (Fixed at “00”)
C: No sale in REG mode C
Enable 0
Disable 1
D: Finalization in REG mode when ST is zero D
Enable 0
Disable 1
E, F, G, H: Not used (Fixed at "0000")
XX: 8 MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 9 MRS = 00000000
A: Not used (Fixed at “0”)
B: EXCHANGE 1 calculation method B
Multiplication 0
Division 1
C: CHECK, CREDIT operation for EX1 C
No 0
Yes 1
D: Printing of EX1 amount for Total and Change D
No 0
Yes 1
E: Printing of EX1 amount for Total VP E
No 0
Yes 1
F. G: Not used (Fixed at "00")
H: Footer graphic LOGO printing at the end of receipt H
No 0
Yes 1
XX: 10 MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 11 MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 12 MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 13 MRS = 00000000
A: Credit totalizer update if RA/PO finalized by Credit
key
A
No 0
Yes 1
B: Separator line in report B
1 line 0
Separator line 1
C: Link PLU print format in REG/MGR mode C
Each PLU 0
Parent PLU text with total amount 1
D, E, F, G, H: Not used (Fixed at "00000")
XXX: 0 ~ 255 sec
2617
XXX
0
TL