4. Clearing Error
4.1 Clearing error code list inside the unit
Step1: Press ENT button for 5 seconds. “OFF” is displayed.
Step2: Press SEL button the display panel show “EL”.
Step3: Press SEL button the display panel show “dAY-P”.
Step4: Press SEL button the display panel show “PS”.
Step5: Press SEL button the display panel show “d-rSL”.
Step6: Press ENT button the display panel show “r_EL”.Press ENT button repeat step5 and
step6 can reset error list.
Step7: Press SEL button the display panel show “r_IP”.Press ENT button repeat step5 ~ step7
can reset integrated power.
Step8: Press SEL button until “OFF” is displayed.
Step9: Press ENT button 5 second, the solar power conditioner will start operation again.
SEL button ENT button
4.2 Clearing “d-xx” error and restart the unit
Press SELECT button on the front panel for 5 seconds, and “d-xx” error will be cancelled.