EN - 8
Electrical connection for your
hob
. Before proceeding with the electri-
cal connection, verify that the current
carrying capacity of the system and
the socket is adequate for the maxi-
mum power rating of the hob.
· Electrical installation of the residen-
ce and the electrical current plug in
use must be grounded and must con-
form with safety regulations.
· If there is no dedicated hob circuit
and fused switch, they must be ins-
talled by a qualied electrician before
the hob is connected.
The fused switch must be easily ac-
cessible once the hob has been ins-
talled.
· Do not use adaptors, multiple soc-
kets and/or extension leads.
This appliance conforms with the re-
quirements of the following EEC Di-
rectives:
1. Vitroceramic hob EEC/73/23 and
93/68, EEC/89/336 relating to radio
interference,
2. EEC/89/109 relating to contact with
foods.
· A circuit breaker with a contact ope-
ning of at least 3 mm, rated 20 A and
delayed functioning type must be ins-
talled inside the supply circuit.
For the touch controlled vitroceramic
hob, the cable must be H05VV-F
3X1,5 mm² / 60227 IEC 53. You will
nd the connection diagram shown on
the back of your appliance.
During installation, please insure that
isolated cables are used. An incorrect
connection might damage your app-
liance. The warranty will not cover
such damages.
All repairs must be carried out by an
authorized service technician or a
qualied electrician.
·Unplug your appliance before each
maintenance. For reconnection,
follow the connection diagrams
carefully.
The supply cable connection can differ
according to the terminal box type.
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~
/