LC-37XD1E/RU SUPPLEMENT
1 – 3
4. Tuner adjustment
6. Initialization to factory settings
1 Setting [Signal]
PAL
PAL split colour bar
䊶Feed the PAL Split Colour Bar (E-12ch) to TUNER.
RF signal
䊶Make sure㵘the PAL colour bar pattern (E-12) has㩷the sync level of
㵘7:3 with the picture level.
[Terminal]
TUNER
㸡100% white
2
Auto adjustment Adjustment process Bring the cursor on [ TUNER ADJ] and press [OK].
performance Page3. [ TUNER ADJ OK] appears when finished.
Adjustment point Adjustment conditions
䈀E-12CH䈁
Adjustment procedure
Caution: When the factory settings have been made, all user setting data, including the channel settings, are
initialized. (The adjustments done in the adjustment process mode are not initialized.) Keep this in
mind when initializing these settings.
1 Factory settings [Factory setting with adjustment process mode]
䊶 Enter the adjustment process mode.
(See to below caution) 䊶 Move the cursor to [Factory Init] on page 2/13.
䊶 Use the R/C 㵘㵘key to select a region from
[EURO/UK/ITALY/FRANCE/RUSSIA] and press the [OK]㵘key.
䊶 “EXECUTING” display appears .
䊶 After a while, "OK" display appears, the setting is completed.
[Factory setting with R/C key]
䊶
Enter the adjustment process mode.
䊶
Push a remote controller code of each destination. (See below )
䊶
It automatically becomes in the process adjustment menu (INIT)
and change FACTORY INIT becomes "EXECUTING" display.
䊶
After a while, "OK" display appears, the setting is completed.
destination R/C code
37XD1K 䊶䊶䊶䊶䊶A8(Hex)
37XD1I 䊶䊶䊶䊶䊶E8(Hex)
37XD1F 䊶䊶䊶䊶䊶E9(Hex)
37XD1R䊶䊶䊶䊶䊶EB(Hex)
37XD1E 䊶䊶䊶䊶䊶FE(Hex)
The following items are initialized in the factory setting.
1. User settings
2. Channel data (e.g. broadcast frequencies)
3. Maker option setting
4. Password data
After adjustments, exit the adjustment process mode.
To exit the adjustment process mode, turn off the MAIN power key.
When the power is turned off with the remoto control, unpulug the AC power cord and plug it back in.
ends by turning off the
MAIN POWER key.
Adjustment item Adjustment conditions Adjustment procedure