MX-EB12N Mirroring Kit
SHARP
Document Solution Centre
31
When the mirroring kit is installed, the two HDD units are named HDD1 (RAID/Mirroring Kit HDD) and HDD2
(Standard Machine HDD). The status of the Mirroring Kit is displayed by one of the following UI Icons within the
operation panel:-
Mirroring Kit is installed.
Mirroring Kit / HDD Trouble.
Mirroring Kit / Rebuilding - Copying the whole contents of one HDD to the other HDD.
Troubleshooting:
Use SIM62-20 to check the HDD status, and refer to the following tables to confirm the relation between
the HDD status and possible remedy :-
Status & Trouble when is displayed:-
SIM 62-20
HDD2
OK
NONE
REBUILDING
ERROR
TROUBLE
HD
D
1
OK
A
A
A
NONE
A
REBUILDING
ERROR
A
TROUBLE
A
Status & Trouble when E7-03 error message is displayed:-
SIM 62-20
HDD2
OK
NONE
REBUILDING
ERROR
TROUBLE
HD
D
1
OK
B
B or C
B
B
B
NONE
B or C
C
C
C
C
REBUILDING
B
C
F
F
F
ERROR
B
C
F
F
F
TROUBLE
B
C
F
F
D or E
Cont’d