MX3500N SIMULATION 7 – 43
<Display item>
27-12
Purpose
Adjustment/Setup/Operation data output/
Check (Display/Print)
Function (Purpose)
Used to display the high-density, half-tone
process control error history and the auto-
matic register adjustment error history.
Section
Process
Item
Specifications
Operation/Procedure
1) When the machine enters Simulation 27-12, the following
screen is displayed.
* Select the display page of process data with [] and [] but-
tons.
* When there is an item over [], the display becomes active
and shifts to the previous page.
When there is no item over [], the display grays out and the
operation is disabled.
When there is an item under [], the display becomes active
and shifts the following page.
When there is no item under [], the display grays out and
the operation is disabled.
* When [CLOSE] button is pressed, the display shifts to the copy
basic screen of the simulation.
* Press [COLOR]/[BLACK] key to execute copying.
<Display item and content descriptions>
27-13
Purpose
Adjustment/Setup/Operation data output/
Check (Display/Print)
Function (Purpose)
Used to display the history of paper feed
time between sensors.
Section
Item
Specifications
Operation/Procedure
1) When the machine enters Simulation 27-13, the following
screen is displayed.
* Select the display page of process data with [] and [] but-
tons.
* When there is an item over [], the display becomes active
and shifts to the previous page.
When there is no item over [], the display grays out and the
operation is disabled.
When there is an item under [], the display becomes active
and shifts the following page.
When there is no item under [], the display grays out and
the operation is disabled.
Display item
RSPF/
DSPF Content
Item
Occurrence date
and time
(Display)
Retry
number
LSU1 99/99/99 99:99:99 8 digits
Common Serial
communication
retry number
history display
LSU2 99/99/99 99:99:99 8 digits
DESK1 99/99/99 99:99:99 8 digits
DESK2 99/99/99 99:99:99 8 digits
INSERTER1 99/99/99 99:99:99 8 digits DSPF
model
INSERTER2 99/99/99 99:99:99 8 digits
FINISHER1 99/99/99 99:99:99 8 digits
Common
FINISHER2 99/99/99 99:99:99 8 digits
DSPF1 99/99/99 99:99:99 8 digits DSPF
model
DSPF2 99/99/99 99:99:99 8 digits
SCAN GAIN
ADJ1
99/99/99 99:99:99 8 digits
Common Scanner gain
adjustment
retry history
display
SCAN GAIN
ADJ2
99/99/99 99:99:99 8 digits
SCAN GAIN
ADJ3
99/99/99 99:99:99 8 digits
SCAN GAIN
ADJ4
99/99/99 99:99:99 8 digits
SCAN GAIN
ADJ5
99/99/99 99:99:99 8 digits
DSPF GAIN
ADJ1
99/99/99 99:99:99 8 digits DSPF
model
DSPF gain
adjustment
retry history
display
DSPF GAIN
ADJ2
99/99/99 99:99:99 8 digits
DSPF GAIN
ADJ3
99/99/99 99:99:99 8 digits
DSPF GAIN
ADJ4
99/99/99 99:99:99 8 digits
DSPF GAIN
ADJ5
99/99/99 99:99:99 8 digits
SIMULATION
NO.
㪉㪎㪄㪈㪈
TEST
TROUBLE PRECOGNITION RESULT
CLOSE
DATE  RETRY
LSU1 99/99/99 999999 99999999
LSU2 99/99/99 999999 99999999
DESK1  99/99/99 999999 99999999
DESK2 99/99/99 999999 99999999
FINISHER1 㧦99/99/99 999999 99999999
FINISHER2 99/99/99 999999 99999999
1/2
0
Display item Content
Occurrence
date and time
(Display)
Error
code
(Digits)
HV_ERR1 High density error history 1 99/99/99
99:99:99
Max. 4
digits
HV_ERR2 High density error history 2 99/99/99
99:99:99
Max. 4
digits
HV_ERR3 High density error history 3 99/99/99
99:99:99
Max. 4
digits
HV_ERR4 High density error history 4 99/99/99
99:99:99
Max. 4
digits
HV_ERR5 High density error history 5 99/99/99
99:99:99
Max. 4
digits
H_TONE ERR1 Half tone error history 1 99/99/99
99:99:99
Max. 4
digits
H_TONE ERR2 Half tone error history 2 99/99/99
99:99:99
Max. 4
digits
H_TONE ERR3 Half tone error history 3 99/99/99
99:99:99
Max. 4
digits
H_TONE ERR4 Half tone error history 4 99/99/99
99:99:99
Max. 4
digits
H_TONE ERR5 Half tone error history 5 99/99/99
99:99:99
Max. 4
digits
AUTO REG
ADJ1
Automatic register
adjustment error history 1
99/99/99
99:99:99
Max. 4
digits
AUTO REG
ADJ2
Automatic register
adjustment error history 2
99/99/99
99:99:99
Max. 4
digits
AUTO REG
ADJ3
Automatic register
adjustment error history 3
99/99/99
99:99:99
Max. 4
digits
AUTO REG
ADJ4
Automatic register
adjustment error history 4
99/99/99
99:99:99
Max. 4
digits
AUTO REG
ADJ5
Automatic register
adjustment error history 5
99/99/99
99:99:99
Max. 4
digits
SIMULATION
NO.
㪉㪎㪄㪈㪉
TEST
TROUBLE PRECOGNITION RESULT(ADJUSTMENT_ERROR)
CLOSE
 DATE  ERROR CODE
HV ERR1㧦99/99/99 999999 9999
HV ERR2 㧦99/99/99 999999 9999
HV ERR3 99/99/99 999999 9999
HV ERR4 㧦99/99/99 999999 9999
HV ERR5 99/99/99 999999 9999
H_TONE ERR1 99/99/99 999999 9999
1/3