MX-EB12N Mirroring Kit
32
SHARP
Document Solution Centre
Troubleshooting:
Case
Trouble
Cause
Advice
A
One HDD status
is OK.
One
HDD status
is
NG
Connection failure of the
connectors and harness of the
mirroring kit
x Replace the HDD & perform the replacement
procedure of the mirroring kit HDD.
x Replace the mirroring kit and perform the
replacement procedure of the mirroring kit
HDD.
B
When at least
one
HDD is OK.
x Communication trouble
through the SATA harness o
f
HDD.
x Trouble of HDD which
indicates the status other t
han
OK.
x Broken data in HDD.
x RAID PWB trouble.
x Replace the cable. Remove and connect.
x Replace the HDD which indicates other th
an
OK and perform the replacement procedu
re
of the mirroring kit
HDD or standard machine
HDD.
x Replace both of the HDD of the mirroring k
it
and that of the machine. Perform the
replacement procedure of th
e mirroring kit
HDD and standard machine HDD.
C
When at least
one
HDD is NONE.
x Communication trouble
through the SATA harness o
f
HDD.
x Connection failure between
the mirroring kit and the
HDD.
x HDD trouble.
x HDD SATA harness &
connector trouble.
x RAID PWB trouble.
x Replace the cable. Remove and connect.
x Check connection between the mirroring
kit
and the HDD.
x Replace the HDD which indicates NONE.
Perform the replacement procedure of th
e
mirroring kit HDD or standard machine HDD.
x Replace the mirroring kit. Perform the
replacement procedure of th
e mirroring kit
HDD or standard machine HDD.
x Replace both of the HDD of the mirroring
kit
and that of the machine.
D
Wh
en in TROU
BLE-
TROUBLE.
x RAID PWB trouble
x (Both or one) HDD trouble
x Replace the mirroring kit. Perform the
replacement procedure of th
e mirroring kit
HDD or standard machine HDD.
x Replace both of the HDD of the mirroring k
it
and that of the machine. Perform the
replacement procedure of th
e mirroring kit
HDD and standard machine HDD.
E
Wh
en in TROU
BLE-
TROUBLE.
(Occurring whe
n
r
eplacing the
HDD)
x The mirroring kit is composed
of HDD's that have different
mirroring informatio
n. (eg. A
HDD which has been used in
the mirroring kit of another
machine is installed.)
x Replace both of the HDD of the mirroring k
it
and that of the machine. Perform the
replacement procedure of th
e mirroring kit
HDD and standard machine HDD.
F
O
ther than cases
B,
C, D, and E
x RAID PWB trouble.
x Both HDD’s trouble.
x Replace the mirroring kit. Perform the
replacement procedure of th
e mirroring kit
HDD or standard machine HDD.
x Replace both of the HDD of the mirroring k
it
and that of the machine. Perform the
replacement procedure of th
e mirroring kit
HDD and standard machine HDD.