SD Card Replacement Procedure
SHARP
Document Solution Centre
35
Only limited data that is stored on the SD Card can be backed up and reinstalled following replacement or
SD card failure. If the SD Card is operating normally before replacement, backup the data (prior to
replacing).
The SD Card includes the following data:-
Partition
Number
Stored Data
Backup
Method
Data
Reinstall
Method
L-101
ICU firmware
data
ICU firmware (Boot/Main)
Lang.sfu
Graph.sfu
Boot animation
Boot (CN)
ARM9 firmware
-
SIM49-
01
(BOOT
cannot
be
installed
again.)
I-101
FAX reception
data
FA
X/Internet Fax reception image data
S
IM66-6
2
-
Replacement Procedure:
When replacing the SD card, be sure to use the specified SD card supplied as a service part only.
The firmware required for booting the MFP device must be included on the SD card that is used in
this machine - Commercially available SD cards do not have this firmware data.
1. Use SIM56-02 to backup the SD card data to a USB memory device.
2. If the operation panel has HOME screen has been customised, backup the SD card data by using
the Device Clone function.
3. When there is FAX/Internet Fax data received, use SIM66-62 to back up the image data to the USB
memory (PDF file type), and then provide the PDF data to the user. (The data cannot be restored to
the machine.)
4. Replace the SD card with a new one.
5. Upgrade the firmware to the latest version.
6. Use SIM66-10 to clear the image send memory. (This is in order to obtain consistency between
the HDD data and the image related memory.)
7. Use SIM56-02 to restore the data backed up in step 1.
8. Restore the data backed up in step 2 by using Device Clone function.
Notes:
x If U2-40 or E7-07 trouble occurs and the error cannot be cancelled using SIM16, this may
indicate an issue or failure of the SD Card – replace the SD Card by following the procedure
detailed above.
Caution:
Data backed up using SIM56-02 must not be installed to another machine otherwise, the adjustment
data will be overwritten and trouble may be generated.