Fuser service check
Diagnostics and troubleshooting
203
Action
Yes
No
Step 1
Check the fuser for proper installation.
Is the fuser properly installed?
Go to step 3.
Go to step 2.
Step 2
Reinstall the fuser.
Does the problem remain?
Go to step 3.
The problem is
solved.
Step 3
Check the LVPS cable on the LVPS and on the JFSNS connector
on the controller for proper connection.
Is the cable properly connected at both ends?
Go to step 5.
Go to step 4.
Step 4
Reconnect the cable.
Does the problem remain?
Go to step 5.
The problem is
solved.
Error code
Description
Action
121.81
Open fuser backup roll thermistor was detected.
See
“Fuser service check” on page 203
.
121.82
Open fuser second backup roll thermistor was
detected.
121.83
Open fuser narrow media backup roll thermistor
was detected.
121.84
Non
contact sensor (BUR) is missing.
121.86
Fuser backup roll thermistor temperature is out of
range.
121.87
Fuser backup roll thermistor temperature change
rate is out of range.
121.88
Fuser second backup roll thermistor temperature is
out of range.
121.89
Fuser second backup roll thermistor temperature
change rate is out of range.
121.90
Fuser non
contact backup roll thermistor
temperature is out of range.
121.91
Fuser non
contact backup roll thermistor
temperature change rate is out of range.