5028
Vertical colored lines or banding check
Leading edge
ABCDE
ABCDE
ABCDE
Trailing edge
Diagnostics and troubleshooting
53
Action
Yes
No
Step 1
a
Enter the Diagnostics menu, and then navigate to:
Advanced Print Quality Samples
>
Advanced Print Quality
Samples
b
Check the test page.
Is only one color producing the defect?
Go to step 2.
Go to step 4.
Step 2
If the affected color is cyan, magenta, or yellow, then replace
the developer unit of the affected color.
If the affected color is black, then replace the imaging unit.
Does the problem remain?
Go to step 3.
The problem is
solved.
Step 3
Replace the photoconductor unit.
Does the problem remain?
Go to step 4.
The problem is
solved.
Step 4
Replace the transfer module. See
“Transfer module removal” on
page 371
.
Does the problem remain?
Go to step 5.
The problem is
solved.
Step 5
Replace the fuser. See
“Fuser removal” on page 370
.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.