EasyManua.ls Logo

Sharp MZ-700 - BASIC Error Message List

Sharp MZ-700
213 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A.
3
BASIC
Error Message List
The BASIC interpreter displays an error message in one
of
the
following formats when an error occurs
during operation.
ji
'
1. < error
type
> error (Direct mode error)
2.
<error
type>
error in line
number
(Run
mode error)
Error messages in format 1 are issued when an error
is detected during execution
of
a direct command
or
entry
of
a program. Error messages in format 2 are issued when an error is detected during program
execution.
Error messages which may be displayed are shown below.
SYNTAX
Error No. Message displayed
1
Syntax error
2
Over flow error
3
Illegal data error
5
String length error
6 Memory capacity error
7
Array def. err
or
8 Linelength error
10
GOSUB
nesting error
11
FOR"'-'NEXT error
12
DEF FN nesting error
~
~
13
NEXT error
14
RETURN error
15
Un
def
. function error
16
Un
def. line
num
. error
17
Can't continue
18
Memory protection
19 Instruction error
20
Can't RESUME error
21
RESUME error
24
READ error
43
Already open error
63
Out
of
file error
65
Printer
is
not
ready
68
Printer mode error
70
Check sum error
IT?<
'
Description.
Syntax error
Numeric
data
used
is
out
of
the
specified range, or
an overflow occurred.
Illegal constant
or
variable was used.
String length exceeded 255 characters.
Memory capacity
is
insufficient.
An
attempt
was made
to
redefine an array
to
a
size greater
than
that
defined previously.
The length
of
a line was
too
long.
The number
of
levels
of
GOSUB nesting exceeded
the
limit determined
by
the
usable memory space.
The
number
of
levels
of
FOR"'-'NEXT loops exceed-
ed
the
limit determined
by
the
usable memory area.
The number
of
levels
of
DEF
FN
nesting exceeded
the limit.
NEXT was used
without
a corresponding FOR.
RETURN was used without a corresponding GOSUB.
An undefined function was called.
An unused line number was referenced.
CONT command cannot be executed.
An
attempt
was made
to
write
data
to
the
BASIC
control area.
Direct mode commands and statements are mixed
together.
RESUME cannot be executed.
An
attempt
was made
to
execute RESUME when no
error had occurred.
READ was used without a corresponding DATA
statement.
An OPEN statement was issued
to
a file which was
already open.
Out
of
file during file read.
Printer
is
not
connected.
Calor
plotter-printer mode error.
Check sum error (during tape read).
----------
----------------
--
------------------------------
--
-----------159

Other manuals for Sharp MZ-700

Related product manuals