PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 23
12-5. TEMP LOG AND TAB
The temperature information is displayed in the Temp log.
12-6. SAVE AND OPEN LOGS
It is possible to save in either original format (.IDR format) or
HTML format (.HTML format).
* To analyze the logs, save the log as the original format (.IDR
format). It is possible to read and display the files saved in
the USB flash drive.
■
Save logs
1) Click [Create Report] to save logs in file.
2) Following window appears, then specify the file name and click
[Save] button.
3) The stored log file can be read with selecting “File” - “Open
Report File” in menu bar.
■
Save logs in HTML format
1) When “File” - “Open Report File” in menu bar is selected, the
dialog for saving is displayed.
2) Specify the file name and push [Save] button.
■
Display log saved in USB flash drive
It is possible to display the log saved in the USB flash drive.
To save the log, refer to the “14-6 SAVE AND OPEN LOGS.”.
1) When “File” - “Open Report File” in menu bar is selected, the
dialog for saving is displayed.
When “xxlog_[Model name]_[Serial number]_[Date].dat” file is
opened, the log is displayed.
■
Display of a system log attached to an abnormality
notification mail
If a log file of the display is attached to an abnormality
notification mail, it can be read by the use of this tool.
1) Save the file attached to an abnormality notification mail.
2) Select “File” - “Open Log File (Binary)” of the menu bar, and
select the saved file
3) The display log when detecting an abnormality is displayed.
12-7. DUMP NVRAM
This tool is provided with the dump acquiring function of the
NVRAM of the information display in order to check the status
when a trouble occurs as well as to acquire and display the logs.
1) Click [Get All Reports] button.
Header Meaning and remark
current temperature Temperature when receiving the
log.
direction Installed Orientation
0:Landscape/1:Portrait
bright control thresh high
temperature error thresh
power off thresh
Temperature of the abnormal
operation of the monitor
minimum temperature Minimum temperature of
monitor
The minimum temperature is
displayed when the power of
the monitor is turned on.
maximum temperature Maximum temperature
The maximum temperature is
displayed when the power of the
monitor is turned on.
bright down count The number of brightness
decrease caused by high
temperature is displayed.
high temperature count The number of high temperature
error is displayed.
power off count The number of being turned off
caused by high temperature is
displayed
Log The latest five logs of Bright
down/ high temperature/ power
off are displayed.