EasyManua.ls Logo

Sharp SMC1585BSA

Sharp SMC1585BSA
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
DESCRIPTION OF LSI
LSI(IZA797DR):
The I/O signals of the LSI(IZA797DR) are detailed in the following table.
noitpircseDO/IlangiS.oN niP
1 VCC IN Connected to GND.
2 VEE IN
Anode (segment) of Fluorescent Display light-up voltage: -30V.
Vp voltage of power source circuit input.
3 AVSS IN
Power source voltage: -5V.
VC voltage of power source circuit input.
4 VREF IN
Reference voltage input terminal.
A reference voltage applied to the A/D converter in the LSI. Connected to GND.(0V)
5 AN7 IN Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is
an analog input terminal from the AH sensor circuit, and connected to the A/D
converter built into the LSI.
6 AN6 IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
7-9 AN5-AN3 IN Heating constant compensation terminal.
10 AN2 IN Input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal(0V).
Door opened; "L" level signal(-5V).
11 AN1 IN
Input signal which communicates the damper open/close information to LSI.
Damper opened; "H" level signal(0V:GND).
Damper closed; "L" level signal(-5V).
12 AN0 IN
Temperature measurement input: OVEN THERMISTOR.
By inputting DC voltage corresponding to the temperature detected by the thermistor,
this input is converted into temperature by the A/D converter built into the LSI.
13 P55 OUT
Digit selection signal.
The relationship between digit signal and digit are as follows;
Digit signal Digit
P03........................... 1st.
P02.......................... 2nd.
P01........................... 3rd.
P00........................... 4th.
P37........................... 5th.
P36.......................... 6th.
P35.......................... 7th.
P55.......................... 8th.
Normally, one pulse is output in every ß
period, and input to the grid of the Fluores-
cent Display.
14 P54 OUT Oven lamp and turntable motor driving signal. (Square Waveform : 60Hz)
To turn on and off the shut-off relay(RY1).
The square waveform voltage is delivered to
the relay(RY1) driving circuit.
15 P53 OUT Convection motor driving signal.
To turn on and off shut-off relay(RY5). "L"
level during CONVECTION; "H" level other-
wise.
16 P52 OUT Cooling fan motor driving signal.
To turn on and off shut-off relay(RY6). "L"
level during both microwave and convection
cooking; "H" level otherwise.
P03
ß(60Hz)
H
L
GND
VP
P02
P01
P00
P37
P36
P35
P55
ON
OFF
During
cooking
L
GND
H.
(Convection)
ON
OFF
During
cooking
L
GND
H.
SMC1585BSA