6 824111
Operation
Shutdown, Flushing, and Storage
NOTE: Antifreeze Flush Kit 802327 is available to
make flushing easier.
CAUTION
If water does freeze in the pressure washer, thaw it
in a warm room before you try to start it. Do not
pour hot water on or into the pump; it could crack
the ceramic plungers.
D If the pressure washer will be exposed to freezing
temperatures, drain all water out of the pump. If it
must be stored in freezing temperatures, flush the
pressure washer with a 50% antifreeze solution,
and relieve the pressure. Flush the pressure
washer before you use it again to remove the
antifreeze.
D Before you store the pressure washer overnight or
transport it, disconnect the water supply, and turn
off the fuel supply valve.
D After each use, wipe all surfaces of the pressure
washer with a clean, damp cloth.
D Perform the appropriate maintenance. See
Maintenance Chart at right.
Maintenance
Observing regular maintenance intervals helps ensure
that you get maximum performance and life from the
pressure washer.
There is a break-in period for the engine and pump.
After you change the oil in these components following
their respective break-in periods, the interval between
required changes is longer.
If the pressure washer is operated in dusty conditions,
these maintenance checks should be made more
often.
Relieve the pressure
(see page 3) before you
proceed with maintenance.
Maintenance Chart
Interval What to do
Daily Clean water inlet screen and filter.
Check engine and pump oil levels.
Fill as necessary. Check gasoline
level. Fill as necessary.
After first
5 hours of
operation
Change engine break-in oil. Drain
oil when warm. Use SAE 30 or
10W–30 detergent oil.
After first 25
hours of
operation
Re-torque exhaust manifold nuts
to 20 ft-lb (27 NSm). Do not over
tighten.
After every
25 hours of
operation
Clean and remove air cleaner
foam. Wash with water and
detergent. Dry thoroughly. Rub
with oil and squeeze to distribute
oil.
After first
50 hours of
operation
Change pump break-in oil. Use
SAE 20 or 30 non-detergent oil.
After every
100 hours of
operation, or
every 3 months
Clean or replace paper air cleaner
cartridge. Tap gently to remove
dirt. Change engine oil. Use SAE
30 or 10W–30 detergent oil.
Re-torque exhaust manifold nuts
to 20 ft-lb (27 NSm). Do not over
tighten.
After every
500 hours of
operation, or
every 6 months
Change pump oil. Use SAE 20 or
30 non-detergent oil.

Related product manuals