EasyManua.ls Logo

Shihlin electric SE2 Series User Manual

Shihlin electric SE2 Series
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.seec.com.tw
ISO 14001
BSMI
REGISTERED
認可登錄
CERT . NO.
4A4E003
ISO 9001
BSMI
REGISTERED
認可登錄
CERT . NO.
4A4Y003
SE2 Series
High Performance Vector control
SE2 Series Inverter

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SE2 Series and is the answer not in the manual?

Shihlin electric SE2 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSE2 Series
CategoryInverter
LanguageEnglish

Summary

Introduction to Shihlin Inverter

Electric specification

Details electrical ratings and specifications for different inverter models, including single-phase and three-phase series.

Installation and wiring

Covers transport, storage, EMC, wiring, and installation precautions for safe and proper setup.

Primary operation

Operating modes of the inverter

Explains the different modes for target frequency and motor starting control, including PU, External, and JOG modes.

Basic Operation Procedures

Step-by-step guides for PU, External, JOG, Communication, and Combined operation modes.

Parameter description

Torque Boost (P.0, P.46)

Adjusts output voltage to improve motor starting torque, essential for V/F mode operation.

Acceleration/deceleration Time Settings

Configures ramp times for motor speed changes, affecting startup, shutdown, and response.

Communication Function

Sets up serial communication parameters like baud rate, protocol, and station number for remote control.

Motor Control Mode Selection (P.300, P.301)

Selects control methods: V/F, Facility Vector, or Sensorless Vector control for optimal performance.

Inspection and Maintenance

Daily inspection

Routine checks of the inverter's operating environment, power supply, and basic status.

Periodical inspection (during stop)

Regular checks of internal components, connections, and insulation resistance when the inverter is off.

Appendix 1 Parameter list

Parameter list overview

Comprehensive list of all inverter parameters, including setting ranges, defaults, and reference pages.

Appendix 2 Alarm Code List

Alarm Code Overview

Lists all alarm codes, their causes, and troubleshooting steps for inverter faults.

Appendix 5 Optional equipment

Expansion board options

Details on available I/O, communication (RS485, Profibus, DeviceNet), and other expansion boards.

Operation panel sets

Information on DU03B, DU05, DU01, and PU01 operation panel sets and their fixing pedestals.