EasyManua.ls Logo

Shihlin electric SS2-021-0.4K User Manual

Shihlin electric SS2-021-0.4K
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Safety Instructions
Safety Instructions
When using Shihlin inverters, please follow the installation to ensure the safety of user and others.
The following instructions will be classified and described by icons
DANGER It means dangerous instructions, and incorrect handling may result in death or
severe injury.
CAUTION It means caution instructions. Incorrect handling may result in injury or property
damage.
It means caution and execution need to be done. Please operate according to the
instructions.
DANGER
Inverters must be used on the location except corrosive gas, water, flammable gas.
Please operate far from flammable substance or explosives.
Please do not lay the inverter on an intense trembling or shaking occasion.
Do not operate wires soaked under oil or water.
Prohibit touching any part in the inverter when power is ON to avoid electric shock.
Three-phase power cannot be connected to terminal U/T1, V/T2, W/T3.
The terminal of the inverter must be correctly grounded.
Do not conduct wiring when the power is ON.
CAUTION
Do not conduct hi-pot test on internal components of the inverter, for semiconductor
is easily damaged by high voltage.
There are CMOS IC components on PCBAs which are especially sensitive to static
electricity. Please do not touch PCBAs before taking anti-static measures.
Even if the motor stops, a charge may still remain in the main circuit terminals of
the inverter with hazardous voltages.
Only qualified persons are allowed to install, wire and maintain the inverter.
After some functions are set, the motor may start immediately once power is ON.
Please choose the safe area to install the inverter, avoiding heat, direct sunlight,
moisture humidity and splashing of droplets.
When wiring between the inverter and motor is too long, it may damage the layer
insulation of the motor. A reactor can be mounted between inverter and motor,
avoiding insulation is damaged.
For the installation power system of rated voltage, it cannot be over 240V for 220
series; it cannot be over 480V for 440 series.
Only qualified personnel familiar with wiring is allowed to perform wiring.
For the installation direction and method, please refer to the regulations.
Make sure to use the temperature in a safe range.
Please follow the installation to use the voltage.
When there are problems in operation, please first unload the motor, after zero-load
operation is OK, and then connect to the machine.
Please confirm whether the inverter power is in line with the motor power.
Before running, please confirm whether the emergency switch can operate normally.
Power wire, U, V, W wires and signal wire should not be stranded, but separately.
Please turn off the power if it is not used for a long time.

Table of Contents

Other manuals for Shihlin electric SS2-021-0.4K

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2-021-0.4K and is the answer not in the manual?

Shihlin electric SS2-021-0.4K Specifications

General IconGeneral
BrandShihlin electric
ModelSS2-021-0.4K
CategoryInverter
LanguageEnglish

Summary

Safety Instructions

Inverter Features and Operation

Installation and Wiring Guidelines

Wiring Principles and Practices

Details wiring methods, noise filters, shielding, grounding, and carrier wave management.

Peripheral Equipment Selection

Primary Operation Modes

Basic Operation Procedures by Mode

Provides step-by-step guides for PU, External, JOG, Communication, and Combined modes.

Pre-Operation Procedures

Pre-Operation Checks and Preparations

Lists essential checks for wiring, connections, and power status before initial operation.

Trial Run and Commissioning

Commissioning Steps and Verification

Details the process for trial running, including checks for rotation, noise, and acceleration/deceleration.

Parameter Description

Torque, Frequency, and V/F Curve Settings

Covers parameters for torque boost, frequency limits, base frequency, and V/F curve adjustments.

Speed Control and Terminal Frequency Inputs

Explains multi-speed, JOG mode, and frequency setting via external terminals and signals.

Acceleration, Deceleration, and Motor Protection

Details parameters for accel/decel times, electronic thermal relay, braking, and stall prevention.

Output Signals and Terminal Functions

Describes multi-function outputs, frequency detection, AM terminals, and communication functions.

Inspection and Maintenance

Alarm Code List

Common Alarm Codes and Troubleshooting

Lists and explains common inverter alarms like OC, OV, ERR, and provides troubleshooting steps.

Specific Alarms and Their Causes

Details alarms such as THT, THN, OHT, OPT, EEP, CPU, OLS, SCP, PIDE, NTC, CPR, OL2, AErr, and their resolution.

Warning Code List

Troubleshootings and Solutions

Motionless Motor and Rotation Issues

Provides checks for motionless motors, reversed rotation, and speed control problems.

Load, Current, and Wiring Troubleshooting

Addresses issues related to heavy loads, motor current, acceleration/deceleration, and wiring length.

European Specification Compliance

Related product manuals