Safety Instructions
Safety Instructions
When using Shihlin inverters, please follow the installation to ensure the safety of user and others.
The following instructions will be classified and described by icons
DANGER It means dangerous instructions, and incorrect handling may result in death or
severe injury.
CAUTION It means caution instructions. Incorrect handling may result in injury or property
damage.
It means caution and execution need to be done. Please operate according to the
instructions.
DANGER
Inverters must be used on the location except corrosive gas, water, flammable gas.
Please operate far from flammable substance or explosives.
Please do not lay the inverter on an intense trembling or shaking occasion.
Do not operate wires soaked under oil or water.
Prohibit touching any part in the inverter when power is ON to avoid electric shock.
Three-phase power cannot be connected to terminal U/T1, V/T2, W/T3.
The terminal of the inverter must be correctly grounded.
Do not conduct wiring when the power is ON.
CAUTION
Do not conduct hi-pot test on internal components of the inverter, for semiconductor
is easily damaged by high voltage.
There are CMOS IC components on PCBAs which are especially sensitive to static
electricity. Please do not touch PCBAs before taking anti-static measures.
Even if the motor stops, a charge may still remain in the main circuit terminals of
the inverter with hazardous voltages.
Only qualified persons are allowed to install, wire and maintain the inverter.
After some functions are set, the motor may start immediately once power is ON.
Please choose the safe area to install the inverter, avoiding heat, direct sunlight,
moisture humidity and splashing of droplets.
When wiring between the inverter and motor is too long, it may damage the layer
insulation of the motor. A reactor can be mounted between inverter and motor,
avoiding insulation is damaged.
For the installation power system of rated voltage, it cannot be over 240V for 220
series; it cannot be over 480V for 440 series.
Only qualified personnel familiar with wiring is allowed to perform wiring.
For the installation direction and method, please refer to the regulations.
Make sure to use the temperature in a safe range.
Please follow the installation to use the voltage.
When there are problems in operation, please first unload the motor, after zero-load
operation is OK, and then connect to the machine.
Please confirm whether the inverter power is in line with the motor power.
Before running, please confirm whether the emergency switch can operate normally.
Power wire, U, V, W wires and signal wire should not be stranded, but separately.
Please turn off the power if it is not used for a long time.

Table of Contents

Other manuals for Shihlin electric SS2-043-1.5K

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2-043-1.5K and is the answer not in the manual?

Shihlin electric SS2-043-1.5K Specifications

General IconGeneral
BrandShihlin electric
ModelSS2-043-1.5K
CategoryInverter
LanguageEnglish

Summary

Introduction of Shihlin Inverter

Installation and Wiring

Guides users through the installation and wiring procedures.

Selection of Peripheral Equipments

Advises on selecting necessary peripheral equipment for the inverter.

Primary Operation

Operation Modes of the Inverter

Explains the different modes available for inverter operation.

Basic Operation Procedures for Different Modes

Details the step-by-step procedures for operating the inverter in various modes.

Operation

Outlines general operational checks and preparation before use.

Parameter Description

Torque Boost (P.0, P.46)

Explains how to set torque boost to improve starting torque.

Range of the Output Frequency (P.1, P.2, P.18)

Details how to set the upper and lower limits for output frequency.

Base Frequency and Base Frequency Voltage (P.3, P.19, P.47)

Describes setting the base frequency and associated voltage for V/F control.

Multi-speed (P.4~P.6, P.24~P.27, P.142~P.149)

Explains how to configure multiple speed settings for operation.

Acceleration/Deceleration Time (P.7, P.8, P.20, P.21, P.44, P.45)

Details parameters for setting acceleration and deceleration times.

DC Injection Brake (P.10, P.11, P.12)

Describes parameters for configuring DC injection braking for stopping the motor.

Starting Frequency (P.13)

Explains how to set the starting frequency for motor startup.

Load Pattern Selection (P.14, P.98, P.99, P.162~P.169)

Allows selection of different VF curves based on load patterns.

Stall Prevention (P.22, P.23, P.66)

Explains how to set stall prevention levels and frequencies.

Acceleration/deceleration Curve Selection (P.29, P.255~P.258)

Allows selection of linear or S-shaped acceleration/deceleration curves.

Regenerative Brake (P.30, P.70)

Explains regenerative brake function selection and duty settings.

Voltage Signal Selection and Target Frequency (P.38, P.73, P.139~P.141)

Explains how to select voltage signals and set target frequencies.

The Input Signal across Terminal 4-5 and the Target Frequency (P.17, P.39)

Details how to configure input signals from terminal 4-5 for target frequency.

Multi-function Output (P.40, P.64, P.74, P.85, P.120 and P.187)

Explains how to configure multi-function output terminals and relays.

Operation Mode Selection (P.79)

Selects the primary operating mode of the inverter.

Multi-function Terminals Function Selection (P.80~P.84, P.86)

Configures the functions assigned to multi-function control terminals.

Programmed Operation Mode (P.100~P.108, P.111~P.118, P.121~P.123, P.131~P.138)

Configures multi-step programmed operation sequences.

Over Torque Detection (P.155~P.156, P.260)

Explains how to set up over torque detection levels and times.

PID Control (P.170~P.183, P.223~P.225)

Details parameters for configuring PID control loops.

Input Signal across Terminal 2-5 (P.192~P.195)

Details configuration of input signals from terminal 2-5 for frequency control.

Input Signal across Terminal 4-5 (P.196~P.199)

Details configuration of input signals from terminal 4-5 for frequency control.

Short Circuit Protection Function (P.287)

Enables or disables short circuit protection for the output end.

Motor Control Mode (P.300 and P.301)

Selects motor control mode and enables auto-tuning functions.

Motor Parameter (P.302~P.309)

Allows inputting motor parameters for optimal performance.

Inspection and Maintenance

Daily Inspection

Outlines routine checks for the inverter's surrounding and operational status.

Periodical Inspection (During Stop)

Details periodic checks performed when the inverter is stopped.

Appendix 2 Alarm Code List

Appendix 3 Warning Code List

Appendix 4 Troubles and Solutions

Related product manuals