Safety Instructions
Safety Instructions
When using Shihlin inverters, please follow the installation to ensure the safety of user and others.
The following instructions will be classified and described by icons
DANGER It means dangerous instructions, and incorrect handling may result in death or
severe injury.
CAUTION It means caution instructions. Incorrect handling may result in injury or property
damage.
It means caution and execution need to be done. Please operate according to the
instructions.
DANGER
Inverters must be used on the location except corrosive gas, water, flammable gas.
Please operate far from flammable substance or explosives.
Please do not lay the inverter on an intense trembling or shaking occasion.
Do not operate wires soaked under oil or water.
Prohibit touching any part in the inverter when power is ON to avoid electric shock.
Three-phase power cannot be connected to terminal U/T1, V/T2, W/T3.
The terminal of the inverter must be correctly grounded.
Do not conduct wiring when the power is ON.
CAUTION
Do not conduct hi-pot test on internal components of the inverter, for semiconductor
is easily damaged by high voltage.
There are CMOS IC components on PCBAs which are especially sensitive to static
electricity. Please do not touch PCBAs before taking anti-static measures.
Even if the motor stops, a charge may still remain in the main circuit terminals of
the inverter with hazardous voltages.
Only qualified persons are allowed to install, wire and maintain the inverter.
After some functions are set, the motor may start immediately once power is ON.
Please choose the safe area to install the inverter, avoiding heat, direct sunlight,
moisture humidity and splashing of droplets.
When wiring between the inverter and motor is too long, it may damage the layer
insulation of the motor. A reactor can be mounted between inverter and motor,
avoiding insulation is damaged.
For the installation power system of rated voltage, it cannot be over 240V for 220
series; it cannot be over 480V for 440 series.
Only qualified personnel familiar with wiring is allowed to perform wiring.
For the installation direction and method, please refer to the regulations.
Make sure to use the temperature in a safe range.
Please follow the installation to use the voltage.
When there are problems in operation, please first unload the motor, after zero-load
operation is OK, and then connect to the machine.
Please confirm whether the inverter power is in line with the motor power.
Before running, please confirm whether the emergency switch can operate normally.
Power wire, U, V, W wires and signal wire should not be stranded, but separately.
Please turn off the power if it is not used for a long time.

Table of Contents

Other manuals for Shihlin electric SS2-021-1.5K

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2-021-1.5K and is the answer not in the manual?

Shihlin electric SS2-021-1.5K Specifications

General IconGeneral
ModelSS2-021-1.5K
CategoryInverter
Power1.5kW
Output Power1.5kW
Frequency50/60 Hz
Protection FeaturesOvervoltage, Short Circuit, Overheating
Input Voltage220-240 V

Summary

Safety Instructions

DANGER

Indicates dangerous instructions, potential severe injury or death from incorrect handling.

CAUTION

Indicates caution instructions, potential injury or property damage from incorrect handling.

User Manual

Delivery Check

Introduction of Shihlin Inverter

Installation and Wiring

Selection of Peripheral Equipments

Power cable specification/pressing connection terminals specification

Primary Operation

Operation Modes of the Inverter

Overview of the inverter's 9 operation modes and 5 operation panel working modes.

Parameter Description

Multi-speed

Parameters for configuring multi-speed operation, allowing up to 16 different speeds.

Acceleration/Deceleration Time

Parameters to set acceleration and deceleration times and curve selections.

Communication Function

Parameters for configuring various communication functions like baud rate, protocol, and data format.

Voltage Signal Selection and Target Frequency

Parameters for selecting voltage signals and setting target frequencies via terminals.

Multi-function Terminals Function Selection (P.80~P.84, P.86)

Parameters for assigning functions to multi-function terminals.

PID Control

Comprehensive parameters for PID control, including gains, limits, and modes for precise regulation.

Inspection and Maintenance

Appendix 2 Alarm Code List

Appendix 4 Troubles and Solutions

Appendix 6 European Specification Compatibility Description