Safety Instructions
Safety Instructions
When using Shihlin inverters, please follow the installation to ensure the safety of user and others.
The following instructions will be classified and described by icons
DANGER It means dangerous instructions, and incorrect handling may result in death or
severe injury.
CAUTION It means caution instructions. Incorrect handling may result in injury or property
damage.
It means caution and execution need to be done. Please operate according to the
instructions.
DANGER
Inverters must be used on the location except corrosive gas, water, flammable gas.
Please operate far from flammable substance or explosives.
Please do not lay the inverter on an intense trembling or shaking occasion.
Do not operate wires soaked under oil or water.
Prohibit touching any part in the inverter when power is ON to avoid electric shock.
Three-phase power cannot be connected to terminal U/T1, V/T2, W/T3.
The terminal of the inverter must be correctly grounded.
Do not conduct wiring when the power is ON.
CAUTION
Do not conduct hi-pot test on internal components of the inverter, for semiconductor
is easily damaged by high voltage.
There are CMOS IC components on PCBAs which are especially sensitive to static
electricity. Please do not touch PCBAs before taking anti-static measures.
Even if the motor stops, a charge may still remain in the main circuit terminals of
the inverter with hazardous voltages.
Only qualified persons are allowed to install, wire and maintain the inverter.
After some functions are set, the motor may start immediately once power is ON.
Please choose the safe area to install the inverter, avoiding heat, direct sunlight,
moisture humidity and splashing of droplets.
When wiring between the inverter and motor is too long, it may damage the layer
insulation of the motor. A reactor can be mounted between inverter and motor,
avoiding insulation is damaged.
For the installation power system of rated voltage, it cannot be over 240V for 220
series; it cannot be over 480V for 440 series.
Only qualified personnel familiar with wiring is allowed to perform wiring.
For the installation direction and method, please refer to the regulations.
Make sure to use the temperature in a safe range.
Please follow the installation to use the voltage.
When there are problems in operation, please first unload the motor, after zero-load
operation is OK, and then connect to the machine.
Please confirm whether the inverter power is in line with the motor power.
Before running, please confirm whether the emergency switch can operate normally.
Power wire, U, V, W wires and signal wire should not be stranded, but separately.
Please turn off the power if it is not used for a long time.

Table of Contents

Other manuals for Shihlin electric SS2 Series

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2 Series and is the answer not in the manual?

Shihlin electric SS2 Series Specifications

General IconGeneral
SeriesSS2 Series
Control MethodV/F control, Sensorless vector control
Cooling MethodFan cooling
Input Voltage3-Phase 380V to 480V
Output Voltage3-Phase, Voltage corresponds to input voltage
Frequency50Hz/60Hz
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
CommunicationRS485 (Modbus RTU)
Operating Temperature-10°C to +50°C
DimensionsVaries depending on model. See datasheet for specific dimensions.
WeightVaries depending on model. See datasheet for specific weight.
Braking UnitBuilt-in braking unit (for models ≤ 2.2kW) External braking resistor can be connected (for models > 2.2kW)

Summary

Safety Instructions

DANGER, CAUTION, and Installation Safety

Essential safety instructions covering dangerous operations, cautions, and installation precautions.

User Manual and Specifications

Terminologies Used

Definitions of key terms used throughout the manual for clarity.

Inverter Identification and Specifications

Covers delivery check, nameplate, type, order codes, and electrical/common specifications.

Installation and Wiring Guide

EMC Compliance, Installation Notices, and Wiring

Guidelines for EMC compliance, installation notices, wiring arrangements, and precautions for safe setup.

Operation and Parameter Configuration

Operation Modes and Procedures

Explains inverter operation modes, basic procedures, and pre-operation checks.

Key Parameter Descriptions

Details critical parameters for torque, frequency, acceleration, braking, PID control, and motor settings.

Communication and Terminal Functions

Parameters for communication, external terminals, and multi-function outputs.

Inspection, Maintenance, and Troubleshooting

Regular Inspections and Component Care

Outlines daily, periodic inspections, component replacement, and testing procedures.

Alarm, Warning, and Troubleshooting Guides

Lists alarm/warning codes and provides troubleshooting steps for common issues.