Parameter Description
Parameter Description
53
5.9 Load Pattern Selection (P.14, P.98, P.99, P.162~P.169)
P.14 “Load pattern selection”
P.98 “Middle frequency 1”
P.99 “Output voltage 1 of middle
frequency”
P.162 “Middle frequency 2”
P.163 “Output voltage 2 of middle
frequency”
P.164 “Middle frequency 3”
P.165 “Output voltage 3 of middle
frequency”
P.166 “Middle frequency 4”
P.167 “Output voltage 4 of middle
frequency”
P.168 “Middle frequency 5”
P.169 “Output voltage 5 of middle
frequency”
Parameter
Factory Setting
Setting Range Remarks
14 0 0~13 There are nine kinds of VF curve when P.14=4~13.
98 3Hz 0~650Hz ---
99 10% 0~100% ---
162 9999 0~650Hz, 9999
---
163 0% 0~100% ---
164 9999 0~650Hz, 9999
---
165 0% 0~100% ---
166 9999 0~650Hz, 9999
---
167 0% 0~100% ---
168 9999 0~650Hz, 9999
---
169 0% 0~100% ---