Parameter Description
Parameter Description
95
5.28 Remote Control Function Selection
(P.61)
P.61 “Remote setting function selection”
If the operation box is located away from the control box, contact signals can be used to perform
the continuous variable-speed operation without using analog signals at the external mode, the PU
mode, the combined mode 1 or the combined mode 5.
Parameter
Factory
Setting
Setting
Range
Remarks
Set
Value
Remote Set
Function
Frequency Setting Storage Function
61 0 0~3
0 No ---
1
Yes
Yes
2 No
3
No
(The remote setting frequency is cleared
by turning off STF/STR.)
<Setting>
• Remote setting function
1. Whether the remote setting function is valid and whether the frequency setting storage function in
the remote setting mode is used is selected by P.61.
Set P.61=1~3 (remote setting function is valid), the function of terminals RM, RH and RL are
changed to acceleration (RH), deceleration (RM) and clear (RL). As shown in the following
Figure:
Wiring of remote control setting

Table of Contents

Other manuals for Shihlin electric SS2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2 Series and is the answer not in the manual?

Shihlin electric SS2 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSS2 Series
CategoryInverter
LanguageEnglish

Related product manuals