Parameter Description
Parameter Description
144
5.80 Restoration of the Parameters to the Default Values (P.998 and P.999)
P.998 “Restoring all parameters to default values”
P.999 “Restoring some parameters to default values”
● Once P.998 is read-out (after the read-out, the screen will display ) and rewritten-in, all the
parameters will be restored to the default values except P.21, P.188, P.189, P.292 and P.293.
● Once P.999 is read-out (after the read-out, the screen will display ) and rewritten-in, all the
parameters will be restored to the default values except P.21, P.188, P.189, P.190~P.191,
P.192~P.195, P.196~P.199, P.292, P.293 and P.300~P.309.
After performing P.998 and P.999, the screen will display , indicating that parameters have
been restored to the default values.
The usage method for the function of restoring all parameters to default values with DU06 is as
follows:
Press to switch to the parameter setting mode, and then rotate
until is displayed.
After pressing , 0 will be displayed. After that, rotate
to change the value to 1 and press
to write in that all the parameters except P.21, P.188, P.189, P.292, P.293 will be restored to the default
value.
The usage method for the function of restoring some parameters to default values with DU06 is as
follows:
Press to switch to the parameter setting mode, and then rotate
until is displayed.
After pressing , 0 will be displayed. After that, rotate
to change the value to 1 and press
to write in that all the parameters except P.21, P.188, P.189, P.190~P.199, P.292, P.293, P.300~P.309 will
be restored to the default value.
When the operation of restoring all parameters to default values and restoring some parameters to
default values is carried out, please make sure that other operations are done after is
displayed on the screen (including DU06) which means that the parameters have restored to
default values.
Note: The parameter P.998 is only executable in the PU mode. For the flow chart of transferring
operation modes, please refer to 4.1.1.

Table of Contents

Other manuals for Shihlin electric SS2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2 Series and is the answer not in the manual?

Shihlin electric SS2 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSS2 Series
CategoryInverter
LanguageEnglish

Related product manuals