6.6 IGBT Module Test
Before check, first dismount the external wires for the main-circuit terminals. Then, set your
multi-meter to the ohm-testing position.
Positive
voltage
Negative
voltage
Normal
result
Positive
voltage
Negative
voltage
Normal
result
Terminal
mark
R/L1 +/P Conducting
Terminal
mark
U/T1 +/P Conducting
S/L2 +/P Conducting
V/T2 +/P Conducting
T/L3 +/P Conducting
W/T3 +/P Conducting
+/P R/L1
Not
conducting
+/P U/T1
Not
conducting
+/P S/L2
Not
conducting
+/P V/T2
Not
conducting
+/P T/L3
Not
conducting
+/P W/T3
Not
conducting
R/L1 -/N
Not
conducting
U/T1 -/N
Not
conducting
S/L2 -/N
Not
conducting
V/T2 -/N
Not
conducting
T/L3 -/N
Not
conducting
W/T3 -/N
Not
conducting
-/N R/L1 Conducting
-/N U/T1 Conducting
-/N S/L2 Conducting
-/N V/T2 Conducting
-/N T/L3 Conducting
-/N W/T3 Conducting

Table of Contents

Other manuals for Shihlin electric SS2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2 Series and is the answer not in the manual?

Shihlin electric SS2 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSS2 Series
CategoryInverter
LanguageEnglish

Related product manuals