SPM-3 Multi-Function Power Meter
User guide
Shihlin Electric & Engineering Corporation
No.23, Chung-Hwa Rd., Huko Hsiang, Hsinchu Taiwan 303 R.O.C
Tel: 886-3-598-1921 Fax: 886-3-598-1480
http:// www.seec.com.tw
20140919
Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SPM-3 and is the answer not in the manual?

Shihlin electric SPM-3 Specifications

General IconGeneral
BrandShihlin electric
ModelSPM-3
CategoryMeasuring Instruments
LanguageEnglish

Summary

Chapter 1 Product Introduction

1.1 SPM-3 Introduction

Overview of the SPM-3 multi-function power meter and its measurement capabilities.

1.2 Caution

Important safety warnings and precautions for using the SPM-3 power meter.

1.2.1 Danger

Specific warnings about hazardous voltages and potential for serious injury or death.

1.3 Product Spec.

Detailed technical specifications of the SPM-3 power meter, including electrical and environmental parameters.

Chapter 2 Installation

2.1 Safety

Essential safety instructions to follow before and during the installation process.

2.2 Mounting

Guidelines for properly mounting the SPM-3 power meter in its intended environment.

Chapter 3 Connection & Wiring

3.1.1 Aux. Power Supply

Instructions for connecting the auxiliary power supply to the SPM-3 meter.

3.1.2 Digital Output

Configuration and connection details for the digital output ports of the SPM-3 meter.

3.1.3 Current Terminal

Information on connecting current transformers (CTs) to the SPM-3 meter's current terminals.

3.1.4 Voltage Terminal

Details on connecting voltage inputs to the SPM-3 meter, including terminal usage for different configurations.

3.2 Wiring diagram

Visual diagrams illustrating wiring connections for various power system configurations.

Chapter 4 Operation & Setting

4.2 Operation

How to navigate through the SPM-3 meter's values and modify settings using the function buttons.

4.3 Setting 「M」、「P」、「E/T」and「V/A」

How to enter and navigate the SPM-3's setting mode using the function buttons.

4.3.1 General Setting (N)

Configuration options for general settings, including address, baud rate, and stop bits.

4.3.2 Clear Setting (C)

Options for clearing various data and settings stored in the SPM-3 meter.

4.3.3 Alarm Setting (A)

Configuring alarm thresholds and behaviors for various electrical parameters.

A8: Over Voltage Alarm setting

Enabling or disabling the over-voltage alarm condition.

A9: Over Current Alarm setting

Enabling or disabling the over-current alarm condition.

A10: Over Frequency Alarm setting

Enabling or disabling the over-frequency alarm condition.

A11: Over Demand Alarm setting

Enabling or disabling the over-demand alarm condition.

A12: Under Voltage Alarm setting

Enabling or disabling the under-voltage alarm condition.

A13: Under Current Alarm setting

Enabling or disabling the under-current alarm condition.

A14: Under Frequency Alarm setting

Enabling or disabling the under-frequency alarm condition.

Chapter 5 Communication

5.7 SPM-3 Parameter

Comprehensive list and description of all Modbus parameters and registers for the SPM-3.

Modbus Module #3 Holding Register : Setup Parameter

Register map for setup parameters in Modbus holding registers.

Modbus Module #5 Input Register : Realtime Data Voltage, Current, Frequency (Float)

Register map for real-time voltage, current, and frequency data (Float) in Modbus input registers.

Modbus Module #6 Input Register : Realtime Data Power Result (Float)

Register map for real-time power results (Float) in Modbus input registers.

Modbus Module #7 Input Register : Energy (Float)

Register map for energy data (Float) in Modbus input registers.

Modbus Module #8 Input Register : Realtime data Demand

Register map for real-time demand data in Modbus input registers.

Modbus Module #9 Input Register : Unbalance Rate

Register map for voltage and current unbalance rate data in Modbus input registers.

Modbus Module #10 Input Register : Voltage Eligibility Rate

Register map for voltage eligibility rate data in Modbus input registers.

Modbus Module #13 Input Register : THD Data

Register map for Total Harmonic Distortion (THD) data in Modbus input registers.

Modbus Module #14 Input Register : Max/Min Data

Register map for maximum and minimum values of various parameters in Modbus input registers.

Modbus Module #16 Input Register : RealtimeData

Register map for real-time data (Voltage, Current, Frequency) in Modbus input registers.

Modbus Module #17 Input Register : Energy Data

Register map for energy data (kWh, kvarh, kVAh) in Modbus input registers.