27(40)
The compressor can't be started frequently because of its characteristics
(Frequent start will shorten its service life.). If emergency shut-down
happens, the compressor will run again 3 minutes later.
4.4 Startup
1) Open the main power switch.
2) Set the temperature of chilling water (if the temp. has already been set, omit
this step). The minimum temperature of this series machine should be set as
7ā„ƒ.
3) Press button to start the water pump.
4) Press button to start the compressor.
4.5 Shutdown
1) Turn off the switch of compressor.
2) Turn off the pump switch. If it adopts the quick molding cycle and low cooling
water temperature, keep continuous running of water pump till the mould
temperature rises to non-condensated temperature, then turn off the pump
switch.
3) Switch the main power switch to OFF position.
Attention!
When main power switch is at ON position, please be careful the electric
shock!
Attention!
As to reduce the machine damage and prolong its service life, please turn
off the machine in correct orders.