Why is the indication flashes on Shinko Denshi Scales?
- EEddie PayneSep 23, 2025
If the indication flashes on Shinko Denshi Scales, the scale may be affected by wind or vibration. Check how and in what environment the scale is installed.
Why is the indication flashes on Shinko Denshi Scales?
If the indication flashes on Shinko Denshi Scales, the scale may be affected by wind or vibration. Check how and in what environment the scale is installed.
What does Err702 mean on Shinko Denshi Scales and how to fix it?
The Err702 error code on Shinko Denshi Scales indicates that the user password was entered incorrectly. To resolve this, verify the password and enter it correctly.
Why do Shinko Denshi Scales display nothing when turned on?
If your Shinko Denshi Scales show no display after being turned on, ensure the DC power supply cable is correctly connected and that the power supply box is switched on. If the issue persists after checking these connections, the electric section of the scale or the power supply box may be faulty, and you should contact the store where you purchased the product.
What does Err705 Err706 mean on Shinko Denshi Scales and how to solve it?
The error codes Err705 and Err706 on Shinko Denshi Scales indicates that the initial zero adjustment was not completed or there is an out-of-range initial zero adjustment error. Check for any wind or vibration and ensure that there is no object on the weighing section during startup.
What does Err100 Err101 Err102 Err103 Err104 mean on Shinko Denshi Scales and how to solve it?
The error codes Err100, Err101, Err102, Err103, and Err104 on Shinko Denshi Scales indicate a communication error in the weighing section. To solve this, check the scale cable connection.
What to do if Shinko Denshi Scales error persists even after calibration?
If the error persists on your Shinko Denshi Scales even after calibration, the scale might be affected by wind or vibration. Consider changing the setting values of relevant functions.
What does Err001 - Err099 mean on Shinko Denshi Scales?
The error codes Err001 through Err099 on Shinko Denshi Scales indicate a system error. Take note of the error number and notify the store where you purchased the product.
What does Err200 mean on Shinko Denshi Scales?
The Err200 error code on Shinko Denshi Scales indicates an internal processing error. Notify the store where you purchased the product.
What does Err716 mean on Shinko Denshi Scales and how to solve it?
The Err716 error code on Shinko Denshi Scales indicates that the span adjustment and span test using the internal weight are not reproducible. To solve this, check for any wind or vibration affecting the scale.
What does Err707 mean on Shinko Denshi Scales and how to resolve it?
The Err707 error code on Shinko Denshi Scales indicates that the upper and lower limit value settings are incorrect. Ensure that the upper and lower limit values are within the weighing range and are not set in reverse order.
Covers critical safety warnings, dangers, and cautions for operation.
Describes powering the scale on/off and performing initial self-checks.
Explains how to set the scale's indication to zero before weighing.
Details subtracting the weight of a container before weighing its contents.
Explains how to select the weighing unit, such as grams (g) or kilograms (kg).
Describes using the scale to display weight as a percentage of a reference weight.
Covers functions for accumulating multiple weights or performing net additions.
Explains setting thresholds to check if a measured value is within a defined range.
Explains automatic correction of zero point fluctuations due to temperature changes.
Allows adjustment of stability criteria for accurate weighing.
Configures how often the scale checks for stability, affecting measurement accuracy.
Adjusts how quickly the scale's display reacts to changes in weight.
Covers inputting, registering, and recalling preset tare weight values.
Details setting reference, upper, and lower limits for the comparator function.
Restores the scale to its original factory default settings.
Describes the critical process of calibrating the scale's accuracy using a known weight.
Lists common error messages, their causes, and recommended countermeasures.
Provides general guidance for diagnosing and resolving common scale issues.
| Model | FZ623Ex |
|---|---|
| Category | Scales |
| Manufacturer | Shinko Denshi |
| Capacity | 620 g |
| Readability | 0.001 g |
| Repeatability (σ) | 0.001 g |
| Linearity | ±0.002 g |
| Display | LCD |
| Interface | RS-232C |
| Maximum Capacity | 620 g |
| Calibration | External |
| Units | g, ct, oz |
| Power | AC Adapter |