ANIUSB Response:
< REP INPUT_METER_MODE PRE_FADER >
< REP INPUT_METER_MODE POST_FADER
>
The ANIUSB will respond with one of these
strings.
Set Input Meter Display Mode
Command String:
< SET INPUT_METER_MODE PRE_FADER >
< SET INPUT_METER_MODE POST_FADER
>
Send one of these commands to the
ANIUSB.
ANIUSB Response:
< REP INPUT_METER_MODE PRE_FADER >
< REP INPUT_METER_MODE POST_FADER
>
The ANIUSB will respond with one of these
strings.
Get Output Meter Display Mode
Command String:
< GET OUTPUT_METER_MODE >
ANIUSB Response:
< REP OUTPUT_METER_MODE PRE_FADER
>
< REP OUTPUT_METER_MODE
POST_FADER >
The ANIUSB will respond with one of these
strings.
Set Output Meter Display Mode
Command String:
< SET OUTPUT_METER_MODE PRE_FADER
>
< SET OUTPUT_METER_MODE
POST_FADER >
Send one of these commands to the
ANIUSB.
ANIUSB Response:
< REP OUTPUT_METER_MODE PRE_FADER
>
< REP OUTPUT_METER_MODE
POST_FADER >
The ANIUSB will respond with one of these
strings.
Get USB Connection Status
Command String:
< GET USB_CONNECT >
ANIUSB Response:
< REP USB_CONNECT ON >
The ANIUSB will respond with one of these
strings.