Get Encryption Status
Command String:
< GET xx ENCRYPTION_CH >
ANIUSB Response:
< REP xx ENCRYPTION_CH ON >
< REP xx ENCRYPTION_CH OFF >
The ANIUSB will respond with one of these
strings.
Reboot ANIUSB
Command String:
< SET REBOOT >
ANIUSB Response:
< REP REBOOT >
Get Error Events
Command String:
< GET LAST_ERROR_EVENT >
Gets the last error that is loged on the
ANIUSB.
ANIUSB Response:
< REP LAST_ERROR_EVENT
{ yyyyyyyyyyyyyyy } >
Where yyyyyyyyyyyyyyy is up to 128
characters.
Get PEQ Filter Enable
Command String:
< GET xx PEQ yy >
Where xx is the PEQ block 07 or 10.
Where yy is the PEQ filter 01-04 within the
block. 00 can be used for all blocks or all
filters.
ANIUSB Response:
< REP xx PEQ yy ON >
< REP xx PEQ yy OFF >
Set PEQ Filter Enable
Command String:
< SET xx PEQ yy ON >
< SET xx PEQ yy OFF >
Send one of these commands to the
ANIUSB.
ANIUSB Response:
< REP xx PEQ yy ON >
< REP xx PEQ yy OFF >
Where xx is the PEQ block 07 or 10.
Where yy is the PEQ filter 01-04 within the
block. 00 can be used for all blocks or all
filters.
Get Input Meter Display Mode
Command String:
< GET INPUT_METER_MODE >