12 Technical data
12.1 General technical data
Mechanical data
SIG350
S4 S8
0 01 1
S3 S7
0 01 1
S2 S6
0 01 1
S1 S5
0 01 1
BF SF LNK1 S T LNK2 UA US
ACT1 ACT2 POWER
PWR1 PWR2
x100 x10 x1
P1 P2
1
2
3
4
5
6
78
62.7
(2.47)
200.1
(7.88)
209.4
(8.24)
35.9
(1.41)
23
(0.91)
25
(0.98)
225.4
(8.87)
Figure 16: Dimensional drawing
Mechanical data
Table 26: Mechanical data
Housingmaterial Plastic (Valox 553)
Enclosure rating as per IEC
60529
IP 67 (only with connected cables)
1)
Dimensions (L x W x H) 225 mm x 63 mm x 37.4mm
Mounting type 2-hole screw mounting
Weight 486 g
1)
If the appropriate cables are not connected to all ports, the free ports must be screwed tight with sealing
plugs (part number 5309189) to ensure IP protection.
Operating conditions
NOTE EMC
This equipment is not intended for use in residential areas and may not provide ade‐
quate protection against radio reception in these environments.