19
8 007 487/10-10-99 Technical Description • LGT © SICK AG • Safety Systems • Germany • All rights reserved
9 Dimensions
9 Dimensions
LGT No. of Enclosure Prot. zone
type beams length height mm
a) b)
015 5 185 155
030 11 335 305
045 17 485 455
060 23 635 605
075 29 785 755
090 35 935 905
32,5
259,5
409,5
559,5
709,5
859,5
0
ø 7,5
M5
2,8
10
15
30
2,8
a)
x
72,5
25
12,5
(159,5)
15
b)
51,5
only LGT 015
1
)
2
)
x = mounting holes
1)
Upper safety field limit is indicated by groove in housing
2)
Lower safety field limit is 15 mm from end of housing
Fig. 26. Dimensions of sender LGTS, receiver LGTE