NOTE
The drag & drop Logic Editor configuration is not accessible via the fieldbus or the REST
API. There, only process data can be used as input or output values for the Logic Editor.
The Logic Editor can use all available signal inputs as sources for the logic application.
In SIG200 this includes:
•
All IO-Link port pins configured as “Digital Input”
•
IO-Link Process Data In from all SX port pins 4 configured to IO-Link mode (Port
S1-S4)
•
Fieldbus Input Process Data
•
REST API Input values
NOTE
It is necessary to upload and assign the IODDs of the devices to be used in the Logic
Editor.
Removing IODDs of devices which has been connected in the Logic Editor could lead to
incompatibilities. This is indicated by the following notification:
Editing Mode
Figure 11: Editing Mode
1. To start your configuration change the operating mode from Run to Maintenance
because the Run mode is a read only mode.
2. Click on Run on the bottom left side and select Maintenance in the drop-down menu.
3. The login password for the maintenance mode is: main
4. Click on Login to select the Maintenance Mode.
8
DEVICE FUNCTIONS
72
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200 8024482.1FJ7 /2022-05-31 | SICK