Using SINAMICS G120 / G120C / S120 Blocksize converters
in marine applications
Question and Answer IconNeed help?

Do you have a question about the Siemens 6SL3210-1KE13-2AF2 and is the answer not in the manual?

Siemens 6SL3210-1KE13-2AF2 Specifications

General IconGeneral
Article Number6SL3210-1KE13-2AF2
Degree of protectionIP20
Input voltage380 ... 480 V 3 AC
Input frequency47 ... 63 Hz
Storage Temperature-40°C to +70°C
Relative Humidity95 %

Summary

Safety Information

Introduction

Components for Marine Applications

3.1 PM240-2 Power Modules

Overview of PM240-2 Power Modules, including voltage, frame size, power range, and integrated filter options.

3.2 Control Units / Control Unit Adapter

Details on SINAMICS Control Units (CU230P-2, CU240E-2, CU250S-2) and adapters (CUA20, CUA31, CUA32).

3.3 Operator Panels

Information on available operator panels like BOP-2 and IOP-2 for SINAMICS converters.

3.4 G120C Compact Converter

Technical specifications of G120C compact converters, covering voltage, power, communication, and filter types.

Referencing Standard Documentation

PM240 System Overview

System Configuration for Marine Applications

Marine-Specific Application Conditions

Temperature Considerations

Discusses ambient temperature impact on converter performance and potential derating in marine environments.

Humidity and Condensation

Addresses the risk of condensation in marine vessels and necessary protective measures for built-in converters.

Salt Mist Restrictions

States that salt mist occurrence is not permissible for the components.

Vibration Stress Requirements

Explains vibration stress from onboard systems and the need for reinforced cabinet design.

EMC Interference Immunity

Covers converter suitability for marine environments regarding interference immunity per IEC standards.

EMC Emitted Interference

Differentiates emitted interference for different voltage devices and filter requirements.

Marine Power Supply Conditions

Highlights weaker marine power supplies, short-circuit ratio, and voltage/frequency stability.

Cabinet Housing Requirements

Details control cabinet protection requirements against pollution, water, and access to active parts.

Marine-Specific Installation Regulations

8.1 Reinforced Control Cabinet Design

Specifies the need for reinforced control cabinet frames due to vibration stress.

8.2 Integration of the Components in the Cabinet

Guidance on installing Control Units separately from Power Modules to mitigate vibration.

8.3 Operator Panel Installed in the Cabinet Doors

Describes installing operator panels (BOP-2, IOP-2) in control cabinet doors.

8.4 Cooling - Control Cabinet Ventilation

Outlines requirements for ventilating control cabinets to dissipate power loss.

8.5 External Auxiliary Power Supply

Explains connecting an external 24-V-DC auxiliary power supply for Control Unit operation.