Ann.LSA VDEW/ZVEI
FNo. Meaning OpFtNo.CAGIBTTypInf
¨©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©©©ª©©ª©©ª©©ª©©©ª©©©
523Interrupted current: Phase L3(I/In) V251 150173
561Circuit breaker manually closed (pulse)C 18 150211
601Current in phase IL1 [%] = M 134133
602Current in phase IL2 [%] = M CA 134133
603Current in phase IL3 [%] = M 134133
604IE[%]= M 134133
1174Circuit breaker test in progress CG 21 GI 151 74
1181Circuit breaker test: General trip C 110 151 81
1451Breaker fail protection is switched offCG 56 GI 166151
1455Breaker failure : fault detection C 227 BT166155
1471Trip by breaker failure protection C 228CA BT p 85
1511Thermal overload prot. is switched off CG 60 GI 167 11
1512Thermal overload protection is blocked CG 61 GI 167 12
1515Thermal overload prot.: Current warningCG 62 GI 167 15
1516Thermal overload prot.: Thermal warningCG 63 GI 167 16
1521Thermal overload protection trip C 64 BT167 21
1721>Overcurrent protection:block stage I>>CG 31 GI 60 1
1722>Overcurrent protection:block stage I> CG 33 GI 60 2
1723>Overcurrent protection:block stage Ip CG 35 GI 60 3
1724>Overcurrent protec.: block stage IE>> CG 32 GI 60 4
1725>Overcurrent protection:block stage IE>CG 34 GI 60 5
1726>Overcurrent protection:block stage IEpCG 36 GI 60 6
1751Overcurrent prot. phase is switched offCG 50 GI 60 21
1756O/C protection earth is switched off CG 51 GI 60 26
1761General fault detection O/C CG144CAGIBT p 84
1762O/C fault detection phase L1 CG145CAGIBT p 64
1763O/C fault detection phase L2 CG146CAGIBT p 65
1764O/C fault detection phase L3 CG147CAGIBT p 66
1765O/C fault detection earth CG148CAGIBT p 67
1771O/C fault detection L1 only C 1616031
1772O/C fault detection L1-E C 1626032
1773O/C fault detection L2 only C 1636033
1774O/C fault detection L2-E C 1646034
1775O/C fault detection L1-L2 C 1656035
1776O/C fault detection L1-L2-E C 1666036
1777O/C fault detection L3 only C 1676037
1778O/C fault detection L3-E C 1686038
1779O/C fault detection L1-L3 C 1696039
1780O/C fault detection L1-L3-E C 1706040
1781O/C fault detection L2-L3 C 1716041
1782O/C fault detection L2-L3-E C 1726042
1783O/C fault detection L1-L2-L3 C 1736043
1784O/C fault detection L1-L2-L3-E C 1746044
1785O/C fault detection E only C 1756045
1791O/C general trip command C 149CA BT p 68
1801O/C fault detection stage I>> phase L1 CG1916046
1802O/C fault detection stage I>> phase L2 CG1926047
1803O/C fault detection stage I>> phase L3 CG1936048
1804O/C time TI>> expired C 1956049
1805O/C protection I>> phase trip C 198CA BT p 91
1811O/C fault detection stage I> phase L1 CG1516050
1812O/C fault detection stage I> phase L2 CG1526051
1813O/C fault detection stage I> phase L3 CG1536052
1814O/C time TI> expired C 1556053
1815O/C protection I> phase trip C 158CA BT p 90
1821O/C fault detection Ip phase L1 CG1816054
1822O/C fault detection Ip phase L2 CG1826055
¥©©©©¦©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©¦©©¦©©¦©©©¦©©¦©©¦©©¦©©©¦©©©¾