Simple troubleshooting
Problem Cause Solution
Display shows
12:00
Power failure or appliance
switched o󰀨 at mains.
Reenter values; do not switch
the appliance o󰀨 at the mains
or select the “Offoption in the
Clock display menu�
Display shows
Milk container
connected?
despite connected milk
container
Container is outside the
range of the sensor
Position the container at the
right edge�
Material e�g� milk carton is
not recognised�
Conrm the display request with
Yes or use the enclosed milk
container
Display shows
“Overvoltage or
undervoltage”
Voltage too high or too low Contact electricity or grid pro-
vider� Have the power supply
checked by an expert�
Display shows
Leave device to cool
Appliance is too hot� Switch o󰀨 appliance for
30 minutes�
Display shows,
for example:
Fault: E0510
The appliance has a fault� Proceed according to the display
screen�
Display shows
Fill bean container
although the container is
already full, or the grinder
is not grinding any beans�
Beans are not falling into the
grinding unit (beans too oily)�
Gently tap the bean container
Possibly change the type of
co󰀨ee. When the bean container
is empty, wipe it with a dry cloth�
Display shows
“Clean brewing unit
Brewing unit is soiled� Clean the brewing unit�
Too much ground co󰀨ee in
the brewing unit�
Clean the brewing unit� Do not
place more than two level meas-
uring spoons of ground co󰀨ee in
the drawer
The mechanism of the
brewing unit is sti󰀨.
Clean the brewing unit, see
the section “Care and daily
cleaning”�
Display shows
Refill with still water or
remove filter ”
Water tank wrongly inserted Insert water tank correctly
Carbonated water in the
water tank�
Fill the water tank with fresh tap
water
Float is stuck in the water
tank�
Remove the tank and clean
thoroughly
New water lter not rinsed
according to instructions, or
water lter used or defective.
Rinse the water lter according
to the instructions and then
switch on, or use a new water
lter
Air in the water lter. Dip the water lter into water
until no more air bubbles
escape, replace the lter.