A5E32105880 ST-H Transducer – QUICK START MANUAL Page EN-3
mmmmm
English
Wiring setups for hazardous area installations
Always check the device nameplate and process device tag to verify the approval rating.
1. Intrinsically Safe wiring
• Refer to
Instructions specific to hazardous area installations (Reference European
ATEX Directive 94/9/EC, Annex II, 1/0/6)
on page 4.
Class I, Div 1,
Gr.A,B,C,D;T3C
Class II, Div 1, Gr. E, F, G
Amb. Temp.: - 40°C to 73°C
PER DWG No.:
1-9470004Z-DX-A
R
Assembled in Canada with domestic and imported parts
Siemens Milltronics Process Instruments, Peterborough
ST-H ULTRASONIC TRANSDUCER
Serial No. GYZ / S1034567
Amb. Temp.: - 20°C to 60°C
V in: 1.77 V r.m.s.; 250 V p; in : 44.2 mA r.m.s.I
0518
II2G
Ex mb IIC T5 Gb
SIRA13ATEX5017X
Warning: Electro-Static Hazard,
Do Not Rub Or Clean On Site
Ex mb IIC T5 Gb
DNV 12.0080 X
ATENÇÃO - RISCO POTENCIAL DE CARGA
ELETROSTÁTICA - VEJA INSTRUÇÕES
KCC-REM-S49
Echomax
OCP 0017
The ATEX certificate can be downloaded from the product
page of our website at: https://www.automation.siemens.com/w1/automation-technology-
st-h-transducer-18736.htm. Go to Support > Approvals / Certificates.
Device nameplate (ATEX/INMETRO/C-TICK/CSA)
CSA Intrinsically Safe connection drawing number 1-9470004Z-DX-A can be downloaded
from the product page of our website at: https://www.automation.siemens.com/w1/
automation-technology-st-h-transducer-18736.htm. Go to Support > Installation Drawings >
Level Measurement > Continuous - Ultrasonic.
ClassI,Div1,Gr.C,D
ClassII,Div1,Gr.E,F,G
Temp. Code: T4 A
(NOT INCLUDING KETONE, HEXANE, ESTER
OR ETHYL ACETATE ATMOSPHERES)
1" NPT, MAX. 20 FT-LB
Assembled in Canada with domestic and imported parts
Siemens Milltronics Process Instruments, Peterborough
ST-H ULTRASONIC TRANSDUCER
,
Serial No. GYZ / S1034567
Amb. Temp.: – 40°C to 73°C
Max. Input Power: 11.5W Max. Input Voltage: 380V rms