Fault Cause and troubleshooting
Coffee tastes burnt. Grinding level is set too fine.
Set a coarser grinding level.
→"Adjusting the grinding level", Page47
Type of coffee is not optimal.
Change the coffee variety.
Coffee temperature setting is too high.
Set the coffee temperature lower.
Coffee grounds are
not compact and are
too wet.
The grinding level is not set optimally.
Adjust the grinder to a coarser or finer setting.
→"Adjusting the grinding level", Page47
Beans are too oily.
Use a different type of bean.
Display shows "Please
insert brewing unit.".
Cover is wrongly inserted.
1. Check whether the brewing unit is inserted correctly
and is securely locked.
2. Push the red lever up to the left.
3. Insert the brewing unit cover.
Display shows "Please
fill water tank." despite
the fact that the water
tank is full.
Water tank is wrongly inserted.
Insert the water tank correctly.
Carbonated water is in the water tank.
Fill the water tank with fresh tap water.
Float is stuck in the water tank.
1. Remove the water tank.
2. Clean the water tank thoroughly.
New water filter was not rinsed as per instructions.
1. Rinse the water filter according to the instructions.
2. Place the water filter into operation.
Air is in the water filter.
1. Immerse the water filter in water with the opening
facing upwards until no more air bubbles escape.
2. Reinsert the filter.
Water filter is old.
Insert a new water filter.
Limescale deposits in the water tank are blocking the
system.
1. Clean the water tank thoroughly.
2. Start the descaling programme.
Display shows "Please
clean brewing unit.".
Brewing unit is soiled.
Clean the brewing unit.

Table of Contents

Other manuals for Siemens EQ.700 classic TP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens EQ.700 classic TP7 Series and is the answer not in the manual?

Siemens EQ.700 classic TP7 Series Specifications

General IconGeneral
Milk FrothingYes
DisplayiSelect Display
Pump Pressure19 bar
Adjustable Coffee StrengthYes
Adjustable TemperatureYes
iSelect DisplayYes
One-Touch PreparationYes
AromaSelectYes
User ProfilesYes
Adjustable Grind SettingsYes
ColorBlack
Power Consumption1500W
ProgrammableYes
GrinderYes
Cleaning SystemAutomatic cleaning
Coffee Output2 cups
Milk SystemIntegrated milk system

Related product manuals