2.2 Service procedures for Gigaset C 350 and 355
Press: "menu-key", 5, 4, 9, ABCD (see table below), o.k.
Pos. acknowledge tone (rising sequence of notes) = Procedure has been accepted.
Feature A B C D (Option)
Read out RFPI number of base station
1 - 0 -
Pause after access code
and
length of dial pause ("P")
1 - 1 1 = 1 sec.
2 = 2 sec.
3 = 3 sec.
4 = 6 sec.
Pause after signal-key
1 - 2 1 = 800 ms
2 = 1600 ms
3 = 3200 ms
Automatic attenuation correction
(dependant on country)
1 - 3 0 = off
1 = on
Time for end of call identification
(to distinguish between 2 ringing pulses of
one call with long pauses between pulses
and 2 separate calls)
1 - 4 0 = 4 sec.
1 = 5.5 sec.
2 = 7 sec.
3 = 11 sec.
4 = 2.5 sec.
Hook-flash-prevention (cradle switch
identification) (short press on cradle switch-
key is extended by SW to prevent that it is
interpreted as a press on the flash-key)
1 - 5 0 = 800 ms
1 = 2000 ms
Pause after line seizure
1 - 6 1 = 1 sec.
2 = 3 sec.
3 = 7 sec.
Music on hold
1 - 7 0 = off 1 = on
Read customer settings
1 - 8 - (see
description below)
*
Suppress first call if SMS is activated
1 - 9 0 = no 1 = yes
System PIN reset
3 76200 - -
Programming data on an address
4 76200 1 Specific code needed
Read out SW-version
(decimal figures)
4 76200 2 Example: 0100200 …
01 = SW-variant
002 = SW-version
00 = Revision
Range of ringing frequency recognition
4 76200 3 0 = 20- 60 Hz
1 = 15- 75 Hz
2 = other settings
Dial pulsing:
pulse pause ratio (make break ratio)
4 76200 4 0 = 1.5 : 1
1 = 2 : 1
CLIP list activation
4 76200 5 0 = on 1 = off
Off-hook CLIP activation
4 76200 6 0 = off 1 = on
Approval test
6 76200 5 -
Working time
7 - 1 - see **