EasyManua.ls Logo

Siemens GM730 User Manual

Siemens GM730
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
008321_b_−−_−− page 1
Papiergrösse = 360 x 270mm
2
3
r=
4
/
4
1
F
min. 6
M4
ø3,2
12
min. 50mm
ø10mm
GMXP0
18
22
TEST POINT
Installation manual 008321_b_--_--
Edition 07.2004
Supersedes −
A5Q00006664
GM730
Seismic detector
Körperschallmelder
Détecteur sismique
Rivelatore sismico
Detector sísmico
Seismische detector
Fire & Security Products
Siemens Building Technologies
Relay shown in energised (non-alarm) condition
Relais in aufgezogenem Zustand (kein Alarm) gezeichnet
Le relais est dessinée à l’état attiré (pas d’alarme)
Il relè è rappresentato in stato eccitato (nessun allarme)
El relé ha sido dibujado en estado excitado (sin alarma)
*
Relais in opgetrokken toestand (geen alarm) getekend
5mm
GMXC2
1918
17
180
80
300300
GMXB0
151413
ø9mm
GMXW0
~60mm
SW1, SW2
GMXS1
GMXD7 GMSW7
Raggio d’azione
Rayon d’action
Wirkradius
Operating radius
Radio de actuación
r =
Aanspreekstraal
Coverage area
Wirkbereich
Domaine d’efficacité
Campo d’azione
Campo de actuación
F =
Aanspreekgebied
20
16
21
1247
Test input
0V
DC 8...16V
Alarm relay
0V
14 15
*
<45R
10 11
spare
Remote
+5V
Tamper
30V
spare
LED
9
4
76
5
8
Option
GMXD7
1110
1 detector
1 Melder
1 détecteur
1 rivelatore
1 detector
1 detektor
2 detectors
2 Melder
2 détecteurs
2 rivelatori
2 detectores
2 detektoren
Solid metal cases
Solide Stahlschränke
Armoires en acier massif
Casse di metallo solido
Cofre de metal macizo
Solide stale kasten
r
r
r
r
r
Question and Answer IconNeed help?

Do you have a question about the Siemens GM730 and is the answer not in the manual?

Siemens GM730 Specifications

General IconGeneral
TechnologyMicrowave
TypeMotion Detector
Protection RatingIP54
Weight150 g
OutputRelay
Operating Temperature-20°C to +55°C

Summary

Seismic Detector GM730 Installation

Application Overview

Details the GM730 seismic detector's features and improvements.

Coverage Area

Explains the detector's operating radius on different materials.

Surveillance of Metal Cases

Describes the detector's monitoring surface on metal enclosures.

Detector Installation Procedures

Covers opening, fastening, direct mounting, and indirect mounting.

Specific Installation Methods

Details on concrete, recessed, and floor box installations.

Installation Accessories

Information on optional components like conduit connection sleeves.

Programming

Commissioning

Technical Data

Maintenance

Approvals

Related product manuals