Installation and connection en
11
volume of refrigerant is indicated
on the rating plate. →"Appliance",
Fig. 1 /
9
, Page14
The weight of the appliance ex works
may be up to 155kg depending on
the model.
The subfloor must be sufficiently
stable to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate. →"Appliance", Fig.
1 /
9
, Page14
Climate
class
Permitted room tem-
perature
SN 10°C to 32°C
N 16°C to 32°C
ST 16°C to 38°C
T 16°C to 43°C
The appliance is fully functional within
the permitted room temperature.
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5°C.
Over-and-under and side-by-side
installation
If you want to install 2 refrigerating
appliances one over the other or side
by side, you must maintain a clear-
ance of at least 150mm between the
appliances. Selected appliances can
be installed without a minimum clear-
ance. Ask your dealer or kitchen
planner about this.
4.3 Installing the appliance
Install the appliance in accordance
with the enclosed installation in-
structions.
4.4 Preparing the appliance
for the first time
1. Remove the informative material.
2. Remove the protective foil and
transit bolts, e.g. remove the ad-
hesive strips and carton.
3. Clean the appliance for the first
time. →Page31
4.5 Connecting the appliance
to the drinking water con-
nection
Requirements
¡ A corner valve must be installed
on the water connection and be
freely accessible following installa-
tion of the appliance.
¡ The water connection is checked
and is of drinking water quality.
1. Rinse the drinking water connec-
tion thoroughly until the drinking
water is no longer cloudy and con-
tains no deposits.
If the drinking water is still cloudy
or contains deposits, install an ex-
ternal water filter system.
2. Install the drinking water connec-
tion according to the enclosed in-
stallation instructions.
4.6 Connecting the appliance
to the electricity supply
1. Insert the non-heating appliance
plug of the power cable into the
appliance.
2. Insert the mains plug of the appli-
ance's power cable in a socket
nearby.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Iq700 KF96D Series and is the answer not in the manual?

Siemens Iq700 KF96D Series Specifications

General IconGeneral
TypeFridge freezer
NoFrostYes
MultiAirflow SystemYes
Home ConnectYes
Installation TypeFreestanding
Noise Level38 dB
Door ColorStainless Steel
Water DispenserYes
Ice MakerYes
Defrost SystemAutomatic

Related product manuals