Overview of Alarms 08/2005
2-918
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
• Manipulated variable filter 1:
• MD 5212 > 0.0
• Manipulated variable filter 2:
• MD 5215 > 0.0
Reactions: - NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy: The bandwidth numerator must be less than twice the blocking frequency.
Speed filter 1:
• BSP bandwidth numerator drive MD 5516: SPEED_FILTER_1_BW_NUMERATOR
• BSP blocking frequency drive MD 5514: SPEED_FILTER_1_SUPPR_FREQ, MD 5516
<= 2 * MD 5514
Manipulated variable filter 1:
• BSP bandwidth numerator drive MD 5212: OUTPUT_VCTRL_FIL_1_BW_NUM
• BSP blocking frequency drive MD 5210: OUTPUT_VCTRL_FIL_1_SUP_FREQ, MD
5212 <= 2 * MD 5210
Manipulated variable filter 2:
• BSP bandwidth numerator drive MD 5215: OUTPUT_VCTRL_FIL_2_BW_NUM
• BSP blocking frequency drive MD 5213: OUTPUT_VCTRL_FIL_2_SUP_FREQ, MD
5215 <= 2 * MD 5213
Program Con-
tinuation:
Clear alarm with the RESET key in all channels. Restart part program.
310760 Axis %1 drive %2 bandwidth denominator greater than double natural frequency
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The bandwidth denominator of a speed or manipulated variable setpoint filter is greater
than twice the natural frequency.
This error message is only issued for the general bandstop filter if:
• Speed filter 1:
• MD 5516 > 0.0 or
• MD 5520 <> 100.0
Reactions: - NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy: The bandwidth denominator of a speed or manipulated variable setpoint filter must be
less than twice the natural frequency.
• Speed filter 1:
• BSP bandwidth drive MD 5515: SPEED_FILTER_1_BANDWIDTH
• BSP blocking frequency drive MD 5514: SPEED_FILTER_1_SUPPR_FREQ

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals